Today’s power systems are based on a centralised system and distribution networks that are considered as passive terminations of transmission networks. The high penetration of Distributed Generation (DG) at the distribution network level has created many challenges for this structure. New tools and simulation approaches are required to address the subject and to quantify the dynamic characteristics of the system. A distribution network or part of it with DG, Active Distribution Network Cell (ADNC), can no longer be considered as passive. An equivalent dynamic model of ADNC is therefore extremely important, as it enables power system operators to quickly estimate the impact of disturbances on the power system’s dynamic behaviour. A dynamic equivalent model works by reducing both the complexity of the distribution network and the computation time required to run a full dynamic simulation. It offers a simple and low-order representation of the system without compromising distribution network dynamic characteristics and behaviour as seen by the external grid. This research aims to develop a dynamic equivalent model for ADNC. It focuses on the development of an equivalent model by exploiting system identification theory, i.e. the grey-box approach. The first part of the thesis gives a comprehensive overview and background of the dynamic equivalent techniques for power systems. The research was inspired by previous work on system identification theory. It further demonstrates the theoretical concept of system identification, system load modelling and the modelling of major types of DG. An equivalent model is developed, guided by the assumed structure of the system. The problem of equivalent model development is then formulated under a system identification framework, and the parameter estimation methodology is proposed. The validation results of the effectiveness and accuracy of the developed model are presented. This includes the estimation of the parameter model using a clustering algorithm to improve the computational performance and the analysis of transformer impedance effects on the ADNC responses. The evaluation of probability density function, eigenvalue analysis and parameter sensitivity analysis for the model parameters are also presented. Typical model parameters for different network topologies and configurations are identified. Finally, the developed equivalent model is used for a large power system application. The accuracy and robustness of the developed equivalent model are demonstrated under small and large disturbance studies for various types of fault and different fault locations.
Identifer | oai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:554158 |
Date | January 2012 |
Creators | Mat Zali, Samila Binti |
Contributors | Milanovic, Jovica |
Publisher | University of Manchester |
Source Sets | Ethos UK |
Detected Language | English |
Type | Electronic Thesis or Dissertation |
Source | https://www.research.manchester.ac.uk/portal/en/theses/equivalent-dynamic-model-of-distribution-network-with-distributed-generation(f4dc9bba-ed4a-4c74-a727-735f3addb6b2).html |
Page generated in 0.0149 seconds