Este trabalho descreve o comportamento eletroquÃmico dos antibiÃticos cefuroxima (CFX) e cefalexina (CFA) por voltametria cÃclica (VC) e o desenvolvimento de metodologia eletroanalÃtica por voltametria de onda quadrada (VOQ) para a determinaÃÃo de CFX e de CFA sobre eletrodo de gota pendente de mercÃrio (HMDE, do inglÃs Hanging Mercury Drop Electrode). CFX apresentou dois processos catÃdicos irreversÃveis em
-0,35 V (pico 1) e em -1,03 V (pico 2), com a participaÃÃo de dois elÃtrons e dois prÃtons tanto para o pico 1 como para o pico 2. Sugere-se que a reaÃÃo de reduÃÃo da molÃcula de CFX ocorre no grupo â C = N â para o pico 1 e no grupo â CH2 â R para o pico 2. Os parÃmetros experimentais e voltamÃtricos foram otimizados, com as respostas sendo obtidas em tampÃo BR pH 2,0,f = 90 s-1, a = 30 mV e ΔEs = 2 mV. Os limites de detecÃÃo (LD) e de quantificaÃÃo (LQ) foram calculados utilizando-se o pico 1, com LD = 4,92x10-9 mol L-1 e LQ = 1,64x10-8 mol L-1 e recuperaÃÃo 109,15% com desvio padrÃo relativo (RSD, do inglÃs Relative Standart Deviation) de 2,39% (n = 3) em eletrÃlito de suporte. A metodologia desenvolvida foi aplicada em amostras de medicamentos, leite bovino e Ãguas naturais, com recuperaÃÃes variando de 96,40 a 129,4%. Para CFA constatou-se a presenÃa de processos catÃdicos em -0,97 V (pico 1) e em -1,2 V (pico 2). Nesse caso, tem-se que a reduÃÃo ocorre na dupla ligaÃÃo do grupo etilÃnico envolvendo a transferÃncia de dois elÃtrons e dois prÃtons. Os parÃmetros experimentais e voltamÃtricos foram avaliados com as respostas otimizadas sendo obtidas em tampÃo BR pH 2,0, f = 100 s-1, a = 30 mV e ΔEs = 4 mV. Considerando-se o pico em -1,2 V, curvas analÃticas foram construÃdas, a partir delas os limites de detecÃÃo e de quantificaÃÃo foram calculados, LD = 1,27x10-8 mol L-1 e LQ = 4,23x10-8 mol L-1 com recuperaÃÃo de 89,19% com RSD = 1,51% (n = 3) em eletrÃlito de suporte. A metodologia foi aplicada na quantificaÃÃo de amostras de medicamentos, leite bovino e Ãguas naturais, com percentuais de recuperaÃÃo variando de 78,45 a 92,13%. Nas metodologias desenvolvidas, foram obtidos baixos valores de LD e de LQ, recuperaÃÃo entre 78,00-130,0% e precisÃo intermediÃria com RSD < 5,00%, mostrando que estas metodologias apresentam Ãtima sensibilidade, eficiÃncia e precisÃo. / The present work describes the electrochemical behavior of the antibiotic cefuroxime (CFX) and cephalexin (CFA) by cyclic voltammetry (CV) and the development of an electroanalytical methodology for CFX and CFA determination on mercury electrodes allied to the square wave voltammetry (SWV). In this work, CFX showed two irreversible reduction peak at -0.35 V (peak 1) and -1.03 V (peak 2), with the participation of two electrons and two protons for both peaks. It is suggested that the reduction reaction of the CFX occurs on the group â C = N â for the peak one and on the group â CH2 â R for the peak two. Under optimized conditions, the results were obtained in BR buffer pH 2.0, f = 90 s-1, a = 30 mV and ΔEs = 2 mV. Considering the peak 1, analytical curves were constructed and the limits of detection (LOD) and quantitation (LOQ) were calculated with LOD = 4.92Ã10-9mol L-1and LOQ = 1.64Ã10-8mol L-1. The recovery in electrolyte was 109.15% with RSD = 2.39% (n = 3). The methodology was applied in raw natural waters, commercial formulations and bovine milk obtaining recovery values from 96.40 to 129.4%. CFA reductions waves are observed at -0.97 V (peak 1) and -1.2 V (peak 2). These reduction waves are attributed to the reduction of ethylenic bond of CFA involving the transfer of two electrons and two protons. The optimized conditions were obtained in BR buffer pH 2.0, f = 100 s-1, a = 30 mV and ΔEs = 4 mV. Considering the peak at -1.2 V, analytical curves were constructed and were calculated with LOD = 1.27Ã10-8mol L-1and LOQ = 4.23Ã10-8 mol L-1. The recovery in electrolyte was 89.19% with RSD = 1.51% (n = 3). The methodology was applied to quantify in raw natural waters, commercial formulations and bovine milk obtaining recovery values from 78.45 to 92.13%. In developed methodologies, we obtained low values of LOD and LOQ, recovery between 78.00 to 130.00% and reproducibility below 5.00%, showing that those methods had excellent sensitivity, precision and efficiency.
Identifer | oai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:5909 |
Date | 10 August 2012 |
Creators | Cristiane Maria Sampaio Forte |
Contributors | Adriana Nunes Correia, Pedro de Lima Neto, Helena Becker, Hugo Barbosa Suffredini, Djenaine de Souza |
Publisher | Universidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em QuÃmica InorgÃnica, UFC, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | application/pdf |
Source | reponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0025 seconds