Orientador: Paulo José Rocha de Albuquerque / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-22T13:59:44Z (GMT). No. of bitstreams: 1
Rodriguez_TiagoGarcia_M.pdf: 30504906 bytes, checksum: c4b35d11f7756b790472830322bab920 (MD5)
Previous issue date: 2013 / Resumo: A presente dissertação tem por objetivo apresentar a caracterização geotécnica do solo de diabásio do Campo Experimental da Faculdade de Engenharia Civil da Unicamp, por meio de ensaios de campo SPT e CPT. Verificar a adequabilidade dos ensaios as condições do solo tropical, lateritico, típico da região de Campinas, por meio de proposicoes de classificação de comportamento de solos e da estimativa de parâmetros geotécnicos, assim como as possíveis correlações, teóricas e empíricas, entre os dois ensaios. Foram utilizados ensaios de cone, mecânico e elétrico, e ensaios SPT com medição de energia. As propostas para classificações dos tipos de solo, através do CPT, utilizadas indicaram duas camadas distintas a primeira de solos de comportamento arenosos a silto-arenosos e a segunda de solos de comportamento siltosos a siltoargilosos, em concordância com a classificação obtida em laboratório. As proposicoes utilizadas para estimativa de parâmetros geotécnicos tiveram que ser ajustadas para o solo do campo experimental. A correlação (qc/pa)/N60 obtida foi de 4 para o solos coluvionar (areno-siltoso) e 2,5 para o solo residual (siltoso) em concordância com os valores encontrados na literatura / Abstract: The purpose of this dissertation is to present the geotechnical characterization of the diabasic soil of the Experimental Field of the Unicamp School of Civil Engineering by means of SPT and CPT field trials, and to check the adequacy of such trials to the conditions of the tropical, lateritic soil, which is typical of the Campinas region by means of propositions to classify the behavior of the soils and estimation of geotechnical parameters, as well as possible theoretical and empirical correlations between the two trials. Cone, mechanical and electrical trials were used as well as SPT trials with measurement of energy. The proposals used to classify the types of soil via CPT indicated two separate layers: the first one with soils with sandy to silty-sandy behavior, and the second layer of soils with silty to silty-clayey behavior, in agreement with the laboratory classification. The propositions used to estimate the geotechnical parameters had to be adjusted to the soil of the experimental field. The correlation (qc/pa)/N60 obtained was 4 for colluvial soil (sandy-silty), and 2.5 for residual soil (silty) in agreement with the values found in the literature / Mestrado / Geotecnia / Mestre em Engenharia Civil
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258775 |
Date | 22 August 2018 |
Creators | Rodriguez, Tiago Garcia |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Albuquerque, Paulo José Rocha de, 1964-, Giacheti, Heraldo Luiz, Barros, Pérsio Leister de Almeida |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Programa de Pós-Graduação em Engenharia Civil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 134 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds