Return to search

Optimization of piezoresistive cantilevers for static and dynamic sensing applications

The presented work aims to optimize the performance of piezoresistive cantilevers in cases where the output signal originates either from a static deflection of the cantilever or from the dynamic (resonance) characteristic of the beam.

Based on a new stress concentration technique, which utilizes silicon beams and wires embedded in the cantilever, the force sensitivity of the cantilever is increased up to 8 fold with only about a 15% decrease in the cantilever stiffness. Moreover, the developed stress-concentrating cantilevers show almost the same resonance characteristic as conventional cantilevers.

The focus of the second part of the present work is to provide guidelines for designing rectangular silicon cantilever beams to achieve maximum quality factors for the fundamental and higher flexural resonance at atmospheric pressure. The applied methodology is based on experimental data acquisition of resonance characteristics of silicon cantilevers, combined with modification of analytical damping models to match the measurement data. To this end, rectangular silicon cantilever beams with thicknesses of 5, 7, 8, 11 and 17 um and lengths and widths ranging from 70 to 1050 um and 80 to 230 um, respectively, have been fabricated and tested. To better describe the experimental data, modified models for air damping have been developed. Moreover, to better understand the damping mechanisms in a resonant cantilever system, analytical models have been developed to describe the cantilever effective mass in any flexural resonance mode. To be able to extract reliable Q-factor data for low signal-to-noise ratios, a new iterative curve fitting technique is developed and implemented.

To address the challenge of frequency drift in (mass-sensitive) resonant sensors, and especially cantilever-based devices, the last part of the research deals with a novel compensation technique to cancel the unwanted environmental effects (e.g., temperature and humidity). This technique is based on exploring the resonance frequency difference of two flexural modes. Experimental data show improvements in temperature and humidity coefficients of frequency from -19.5 to 0.2 ppm/˚C and from 0.7 to -0.03 ppm/%RH, respectively. The last part of the work also aims on techniques to enhance or suppress the flexural vibration amplitude in desired overtones.

Identiferoai:union.ndltd.org:GATECH/oai:smartech.gatech.edu:1853/28247
Date03 April 2009
CreatorsNaeli, Kianoush
PublisherGeorgia Institute of Technology
Source SetsGeorgia Tech Electronic Thesis and Dissertation Archive
Detected LanguageEnglish
TypeDissertation

Page generated in 0.0026 seconds