The research searches for an identification strategy which is able to recognize three small-wattage metal halide lamps rated at powers of 20-W, 35-W and 70-W from three world-wide prominent brands of GE, OSRAM and PHILIPS. A two-stage constant-power starting scenario is adopted to successfully start all three kinds of lamps without causing a tremendous power during the identification process.
At the first stage, the tested lamps are started by a constant power of 25 W. The 20-W lamps can be distinguished from the others by their relatively high lamp voltages at the 30th seconds after being ignited. Then, the other lamps are driven up to 35 W to manifest the voltage difference of between the 35-W and 70-W lamps, and thus can be recognized at the 40th seconds. After being made out, the lamps are operated at their rated powers. Eventually, a verification checking with protection is introduced to prevent the tested lamps from over power operation.
Experiments have been done on numerous new and aged lamps. The experimental results evidence that the electronic ballast with the proposed identification strategy can recognize three lamps¡¦ rated powers correctly during the starting transition, and drive the lamp to its rated power before entering the steady-state.
Identifer | oai:union.ndltd.org:NSYSU/oai:NSYSU:etd-0731108-135741 |
Date | 31 July 2008 |
Creators | Tsai, Wen-Tien |
Contributors | Ray-Lee Lin, Ching-Lung Chu, Chin-Sien Moo, Ming-Tsung Tsai, Hau-Chen Yen |
Publisher | NSYSU |
Source Sets | NSYSU Electronic Thesis and Dissertation Archive |
Language | Cholon |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731108-135741 |
Rights | not_available, Copyright information available at source archive |
Page generated in 0.0022 seconds