Orientador: Luiz Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T17:59:19Z (GMT). No. of bitstreams: 1
Erhardt_MariaCarolinaGuilherme_M.pdf: 5117640 bytes, checksum: d255d8edb48804d7128e30ab7907508a (MD5)
Previous issue date: 2003 / Resumo: O objetivo deste estudo in vitro foi determinar a influência de superfícies dentinárias desmineralizadas, normais e hipermineralizadas na resistência adesiva (RA) dos sistemas adesivos Clearfil Liner Bond 2V / Kuraray Co. (CLB), Single Bond /3M (SB) e OptiBond Solo P/us / Kerr (OSP). Noventa incisivos bovinos foram selecionados, tendo suas superfícies vestibulares desgastadas com lixas de carbeto de silício em granulação decrescente. Os dentes foram aleatoriamente separados em três grupos, sendo submetidos a diferentes padrões de ciclagem de pH: G1 - dentina desmineralizada (DD)i G2 - dentina hipermineralizada (DH) e G3 - dentina normal (DN). Cada grupo, com seus respectivos padrões de superfície, foi novamente dividido por aleatorização em três subgrupos, para que recebessem a aplicação de um dos três sistemas adesivos, de acordo com a recomendação dos fabricantes. Blocos de compósito Filtek Z250 / 3M com altura de 5 mm foram incrementalmente confeccionados, e após 24 h de armazenagem em água destilada a 37 °C, os dentes foram preparados para serem submetidos ao teste de microtração. Dispostos em cortadeira metalográfica de precisão, os dentes foram seriadamente seccionados em fatias de 1,0 mm de espessura paralelamente ao longo eixo dental. Em seguida, dispositivos hour glass foram manualmente confeccionados com o auxílio de pontas diamantadas de granulação fina em alta rotação, com área adesiva final de 0,8 mm2. Os espécimes foram afixados individualmente em um dispositivo de microtração (MT Jig), acoplada em máquina de ensaio universal / EMIC, com velocidade de 0,5 mm/min. Após o teste, as duas porções fraturadas foram avaliadas em microscópio óptico (40x). Os valores de RA foram submetidos aos testes de análise de variância (ANOVA 2 fatores) e Tukey, com nível de significância de 5%. Os valores médios, expressos em MPa, foram: DN;SB= 31,05; DN/OSP= 24,49; DH;SB= 23,97; DH/CLB= 19,32; DN/CLB= 19,00; DH/OSP= 17,84; DD/CLB= 15,81; DD;SB= 13,62i DD/OSP= 5,22. Houve interação estatística entre os sistemas adesivos e os tipos de dentina avaliados. Em DN, os sistemas adesivos SB e OSP foram significativamente mais efetivos que o adesivo CLB. Em DD, os adesivos SB e CLB apresentaram os maiores valores de RA. Em DH, todos os sistemas adesivos se comportaram de maneira semelhante. Não foi possível observar um benefício claro advindo da utilização de um único sistema adesivo em todos os níveis de mineralização dentinária / Abstract: The purpose of this in vitro study was to investigate the effect of dentin mineralization level: demineralized, normal or hypermineralized, on microtensile bond strength of the adhesive systems Clearfil Liner Bond 2V / Kuraray Co. (CLB), Single Bond / 3M (SB) and OptiBond Solo Plus / Kerr (OSP). 90 freshly extracted incisive bovine teeth were selected, thoroughly cleaned and mechanically polished with wet silicon carbide papers. Teeth were randomly assigned into three groups, which were submitted to different pH-cycling models: Group I - demineralized dentin (DD); Group II - hypermineralized dentin (HD) and Group III normal dentin (ND). Each group, with its specific mineralization pattern, was randomly reassigned into three subgroups, in order to receive one of each adhesive application, according to manufacturers' instructions. Resin "crowns" with 5 mm high were incrementally constructed with Filtek Z250 /3M composite resin, and after 24 h of storage in distilled water at 37°C, teeth were prepared to micro-tensile testing. Samples were serially sectioned on a precision cutter in 1 mm slices, parallel to the dental long axis; and with diamond points, the hour glass devices were trimmed resulting in a cross-sectional area of 0.8 mm2. Each specimen was indMdual1y tested on a microtensile device (MT Jig) attached to a universal testing machine / EMIC with a crosshead speed of 0.5 mm/min. After testing, each specimen was visually evaluated. The bond strengths were statistically evaluated with two-way ANOVA and Tukey's test (p<0.05). The mean values obtained, recorded in MPa, were: ND;SB= 31.05; ND/OSP= 24.49; HD;SB= 23.97; HD/CLB= 19.32; ND/CLB= 19.00; HD/OSP= 17.84; DD/CLB= 15.81; DD;SB= 13.62; DD/OSP= 5.22. The statistical analysis showed a significant (p<0.05) interaction between the adhesive systems and the dentin substrates evaluated. SB and OSP presented the higher tensile bond strength values on ND. In terms of tensile bond strengths to DD, the highest mean values originated from SB and CLB. Regarding the HD, no differences were found among the adhesive systems evaluated. It could not be observed a real benefit from a unique adhesive system in all dentin mineralization levels / Mestrado / Dentística / Mestre em Clínica Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289750 |
Date | 31 January 2003 |
Creators | Erhardt, Maria Carolina Guilherme |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Pimenta, Luiz Andre Freire, 1965-, Paulillo, Luis Alexandre Maffei Sartini, Cardoso, Paulo Eduardo Capel |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 167p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0033 seconds