This work can be viewed in three separate sections, each of which build off of the prior. The first part of this study examined the flow in a 1/16th scale calandria test section based on a typical CANDU moderator layout. The experiments utilized forced flow supplied to the vessel and electrical heated rods to mimic the heat flow from calandria tubes. The size of the vessel, flow rates, and power levels were used to scale the experiments such that the provided representative temperature fields. The temperature field inside the vessel was measured and shown to compare well with CFD predictions over a wide range of inlet conditions and power levels. Additionally, this work addressed the scaling distortions in the experiment which occurred due to physical limitations when performing experiments at 1/16 scale (e.g., a smaller number of heater rods with a larger diameter were used in the experiment because at 1/16-scale direct fabrication of 390 fuel channel simulators is not feasible). The work proposed the H factor addition to the Ar. This additional scaling criteria was shown to better maintain the flow regimes expected CANDU moderators by taking into account distortions introduced by surface heating instead of volumetric heating in addition to the reduction in total number of tubes. While this work involved forced convective flows at the inlet of the vessel, in some regions of the calandria buoyancy induced forces were sufficiently high such that these phenomena altered the direction and magnitude of the flows as compared to purely forced convective behavior. Hence further work, discussed below, was initiated to better understand and measure these local phenomena where buoyancy forces are of similar magnitude as those of forced convection. Such local conditions we have terms mixed convection regime for the purposes of this thesis.
The second part of this work further examined the mixed convection between a subset of the CANDU calandria tubes, namely how does a lower tube effect the mixed convection heat transfer of the upper tube in an inline arrangement. To isolate and measure the phenomena with sufficient detail, a small number of tubes was studied and advanced diagnostics such as Particle Image Velocimetry (PIV) and Laser Induced Fluorescence (LIF) were employed. This study combined fluid velocity, temperature and wall temperature measurements with CFD simulations to develop a mechanistic model and understanding of the effect of natural convection plumes from lower elevations on the natural circulation phenomena on an upper cylinder. Superposition of the natural convection phenomena combined with pseudo forced convection effects from the lower elevation cylinder’s plume was used to model the mixed convection phenomena. This model was shown to perform well, with nearly all data being predicted to with +-20% for experiments performed in this work, and experiments in literature.
A major finding from the preceding discussion is the importance of the lower elevation plume velocity on the local phenomena on the upper cylinder. The third section further expanded upon the prior two by replacing the lower cylinder with a diffuser nozzle which could provide a forced convective component with accurately defined velocities. Such measurements allow for accurate definition of the local Ri number and allowed full access for instrumentation to observe the velocity fields. The major contribution of this work was a flow regime map that defined the phenomena around a heated cylinder under mixed convection conditions. Additionally, the establishment of a database of fluid temperature and velocity measurements for a wide range of Ri was also developed and used to further validate CFD predictions. / Thesis / Doctor of Philosophy (PhD)
Identifer | oai:union.ndltd.org:mcmaster.ca/oai:macsphere.mcmaster.ca:11375/28047 |
Date | 11 1900 |
Creators | Hollingshead, Christopher |
Contributors | Novog, David, Engineering Physics |
Source Sets | McMaster University |
Language | en_US |
Detected Language | English |
Type | Thesis |