The release of flammable and toxic chemicals in petrochemical facilities is a major concern when designing modern process safety systems. While the proper selection of the necessary types of gas detectors needed is important, appropriate placement of these detectors is required in order to have a well-functioning gas detection system. However, the uncertainty in leak locations, gas composition, process and weather conditions, and process geometries must all be considered when attempting to determine the appropriate number and placement of the gas detectors. Because traditional approaches are typically based on heuristics, there exists the need to develop more rigorous optimization based approaches to handling this problem. This work presents several mixed-integer programming formulations to address this need.
First, a general mixed-integer linear programming problem is presented. This formulation takes advantage of precomputed computational fluid dynamics (CFD) simulations to determine a gas detector placement that minimizes the expected detection time across all scenarios. An extension to this formulation is added that considers the overall coverage in a facility in order to improve the detector placement when enough scenarios may not be available. Additionally, a formulation considering the Conditional-Value-at-Risk is also presented. This formulation provides some control over the shape of the tail of the distribution, not only minimizing the expected detection time across all scenarios, but also improving the tail behavior.
In addition to improved formulations, procedures are introduced to determine confidence in the placement generated and to determine if enough scenarios have been used in determining the gas detector placement. First, a procedure is introduced to analyze the performance of the proposed gas detector placement in the face of “unforeseen” scenarios, or scenarios that were not necessarily included in the original formulation. Additionally, a procedure for determine the confidence interval on the optimality gap between a placement generated with a sample of scenarios and its estimated performance on the entire uncertainty space. Finally, a method for determining if enough scenarios have been used and how much additional benefit is expected by adding more scenarios to the optimization is proposed.
Results are presented for each of the formulations and methods presented using three data sets from an actual process facility. The use of an off-the-shelf toolkit for the placement of detectors in municipal water networks from the EPA, known as TEVA-SPOT, is explored. Because this toolkit was not designed for placing gas detectors, some adaptation of the files is necessary, and the procedure for doing so is presented.
Identifer | oai:union.ndltd.org:tamu.edu/oai:repository.tamu.edu:1969.1/150991 |
Date | 16 December 2013 |
Creators | Legg, Sean W |
Contributors | Laird, Carl D, Mannan, M. Sam, Glover, Charles, Curry, Guy |
Source Sets | Texas A and M University |
Language | English |
Detected Language | English |
Type | Thesis, text |
Format | application/pdf |
Page generated in 0.0028 seconds