Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-07T11:50:35Z
No. of bitstreams: 1
2014_MarcosDiegodeCastroeSilva.pdf: 5319545 bytes, checksum: ef30c1f74f16c67ff12e33234b09e69d (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-17T12:09:44Z (GMT) No. of bitstreams: 1
2014_MarcosDiegodeCastroeSilva.pdf: 5319545 bytes, checksum: ef30c1f74f16c67ff12e33234b09e69d (MD5) / Made available in DSpace on 2014-11-17T12:09:44Z (GMT). No. of bitstreams: 1
2014_MarcosDiegodeCastroeSilva.pdf: 5319545 bytes, checksum: ef30c1f74f16c67ff12e33234b09e69d (MD5) / Dos problemas associados a uma rede elétrica cuja alimentação possui a qualidade da energia comprometida, pode-se citar o desequilíbrio de tensão. Trata-se de um fenômeno que é definido para sistemas trifásicos como uma condição na qual as tensões apresentam módulos diferentes entre si, ou defasagem angular entre as fases diferentes de 120º, ou ainda, estas duas condições simultaneamente. Devido ao fato de motores de indução trifásicos (MIT) usualmente serem conectados em configurações que não permitem a circulação de corrente de sequência zero, verifica-se que há uma lacuna em estudos envolvendo os efeitos de tal componente sobre máquinas elétricas. Os principais documentos normativos priorizam o indicador de desequilíbrio de tensão de sequência negativa. Muitas vezes, o emprego de um índice que contemple a componente de sequência zero não é obrigatório. Considerando-se os aspectos ora mencionados, este trabalho que tem como objetivo avaliar os efeitos das componentes de sequência positiva, negativa e zero sobre as temperaturas de um MIT. Inicialmente, é projetada e desenvolvida uma ferramenta de controle da tensão de entrada e geração de relatórios que contêm as leituras de inúmeras grandezas pertinentes ao motor. Em seguida, propõem-se um modelo térmico e uma rede neural artificial para estimação das temperaturas nas três fases dos enrolamentos do estator e elaboram-se criteriosamente bancos de dados que permitem análises eficientes e representativas dos principais efeitos das componentes de sequência sobre as temperaturas do MIT. Neste estudo, são empregados resultados experimentais (cerca de 40 mil) e oriundos de simulações computacionais (aproximadamente 2,6 milhões). Diante das investigações realizadas nesta dissertação mostra-se que os indicadores convencionalmente empregados para a quantificação do desequilíbrio de tensão se caracterizam inadequados. Além do mais, verifica-se que os ângulos das componentes simétricas, os quais não são contemplados nos indicadores de desequilíbrio convencionais, são os parâmetros que mais exercem influência nas correntes e temperaturas de um MIT. _______________________________________________________________________________________ ABSTRACT / Voltage unbalance is a problem associated with an electrical grid whose power quality is compromised. This phenomenon is characterized by alteration in the three-phase pattern, which is provided by a balanced system, consisting of equal voltage magnitude and phase shift of 120° between them. Three-phase induction motors (TIM) are usually connected in configurations that do not allow zero sequence current flow. For this reason, there is a gap in studies involving the effects of such component on electrical machines. The main normative documents prioritize the negative voltage unbalance indicator. Most often, the use of an index that includes the zero sequence component is not required. Considering the aforementioned aspects, this study has the objective of evaluating the effects of positive, negative and zero components on the temperature of a three-phase induction motor. In order to do this, experimental results (about 40 thousand values) and computer simulations (approximately 2.6 million values) are employed. Moreover, a series of tasks are accomplished in this work, such as: a design and development of a tool to control the voltage and generating reports that contain numerous readings related to the motor; a proposal of a thermal model and establishment of an artificial neural network in order to estimate temperatures in three phases of the stator windings; and a preparation of databases that allow efficient and representative analysis of the main effects of the symmetrical components on the temperatures of the TIM. By means of the investigations conducted in this study, it is shown that the indicators conventionally used to characterize voltage unbalance are inadequate to properly quantify this phenomenon. Moreover, it appears that the angles of symmetrical components (which are not taken into account in conventional voltage unbalance indicators) are the parameters that most influence the currents and temperatures of a TIM.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/16898 |
Date | 24 March 2014 |
Creators | Silva, Marcos Diego de Castro e |
Contributors | Ferreira Filho, Anésio de Leles |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds