Return to search

Effect of light curing tip distance and immersion media on the degree of conversion, sorption and solubility of methacrylate and silorane-based composites = Efeito da distância de fotoativação e meios de imersão sobre o grau de conversão, sorção e solubilidade de compósitos à base de metacrilato e silorano / Efeito da distância de fotoativação e meios de imersão sobre o grau de conversão, sorção e solubilidade de compósitos à base de metacrilato e silorano

Orientador: José Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T19:12:21Z (GMT). No. of bitstreams: 1
Miranda_DiogodeAzevedo_D.pdf: 917256 bytes, checksum: c14c6c829d5ff17a27a9aaa10821f2a8 (MD5)
Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar o efeito de três distâncias de fotoativação (0mm, 3mm e 6mm) e quatro meios de imersão (saliva artificial - AS, Plax FreshMint - PFM, Plax Sem álcool - PAF e Plax Whitening - PW) sobre a sorção e solubilidade de compósitos à base de metacrilato (Filtek Z350) e silorano (Filtek P90). Os espécimes foram confeccionados a partir de uma matriz de teflon de 6mm de diâmetro por 1mm de profundidade, onde o compósito foi inserido em incremento único e fotoativado por 20 segundos. Para controlar as distâncias de fotoativação, foi utilizado um dispositivo acoplado a um paquímetro digital. Para o teste de grau de conversão (GC) foram confeccionadas 30 amostras (n=5), de acordo com o tipo de resina e a distância de fotoativação. A leitura dos espectros foi realizada por um espectrômetro de raios infravermelhos transformado de Fourier (FTIR). Para os testes de sorção e solubilidade foram confeccionados 120 espécimes (n=5), de acordo com as variáveis compósitos, distâncias de fotoativação e meios de imersão. As amostras foram armazenadas em um dissecador com sílica em gel até a obtenção de uma massa inicial estável (m1). Após estabilização da massa inicial, o diâmetro e a espessura foram aferidos em quatro pontos equidistantes utilizando paquímetro digital. Durante 30 dias, as amostras foram imersas duas vezes ao dia, durante dois minutos nos diferentes enxaguatórios e, entre cada ciclo de imersão (12 horas de intervalo), permaneciam em saliva artificial. O grupo controle permaneceu em saliva artificial durante todo período. Por fim as amostras foram retiradas das soluções e pesadas novamente numa balança de precisão para obtenção da nova massa (m2) e, em seguida, colocadas no dessecador até a obtenção de uma massa final estável (m3). Os dados de GC% foram analisados por meio de análise de variância (ANOVA) em esquema de parcelas subdivididas e as comparações múltiplas foram feitas pelo teste de Tukey, considerando o nível de significância de 5%. Os resultados mostraram que não houve diferença estatística no GC% entre as superfícies testadas (topo e base); entretanto, quando a fotoativação foi realizada a 6 mm de distância, tanto a superfície base quanto a de topo, apresentou menores valores de GC, independente do tipo de compósito. Para sorção, os dados foram analisados por ANOVA two way e teste de Tukey, considerando o nível de significância de 5%. O compósito à base de metacrilato apresentou maiores taxas de sorção que o compósito à base de silorano; a saliva não influenciou a sorção, independente da distância e do compósito. O PW demonstrou alterar significativamente a sorção, independente do tipo de compósito. Os dados de solubilidade foram analisados pelos testes não paramétricos de Kruskal Wallis e Dunn, com nível de significância de 5%. Para todas as distâncias e soluções, os valores obtidos foram negativos / Abstract: The main purpose of this study was to evaluate the effect of three light curing tip distances (0mm, 3mm and 6mm) and four immersion media (artificial saliva - AS, Plax FreshMint - PFM, Plax Sem álcool - PAF and Plax Whitening - PW) on sorption and solubility of metacrilate-based (Filtek Z250) and silorane-based (Filtek P90) composites. The specimens were made from a Teflon mold of 6mm of diameter by 1mm deep, where the composite was inserted in single increment and light-cured for 20 seconds. To control the photoactivation distances, it was used a device coupled to a digital pachymeter. For the Degree of Conversion test (DC%) were prepared 30 samples (n=5), according to the type of resin and the distance of photoactivation. The reading of the spectrums was performed by a ray spectrometer, Fourier transform infrared (FTIR). For sorption and solubility tests were prepared 120 specimens (n=5), according to the variable of the composites, distances of photoactivation and immersion media. The samples were stored in a desiccator with silica gel to obtain a stable initial mass (m1). After stabilization of the initial mass, diameter and thickness were measured at four equidistant points using a digital pachymeter. During 30 days the samples were immersed twice daily for two minutes in the different mouthrinses between each emersion cycle (12 hour interval) remained immersed in artificial saliva. The control group remained in artificial saliva during the entire period. Finally the samples were removed from the solution and re weighed on a precision scale to obtain the new mass (m2) and then placed in a desiccator to obtain a final stable mass (m3). DC% data were analyzed by analysis of variance (ANOVA) in subdivided plots and multiple comparisons were made by Tukey test, considering a significance level of 5%. The results did not show any statistical difference between the DC tested surfaces (top and base), however, when the polymerization was performed at 6 mm of distance, both the surface base and the top, presented lower DC% values regardless of the composite type. For sorption, data were analyzed by two-way ANOVA and Tukey test, considering a significance level of 5%. The methacrylate-based composite had higher rates of sorption that the composite silorane-based; saliva did not influence the sorption, regardless of distance and the composite. PW demonstrated significantly change the sorption, regardless of the type of composite. The solubility data were analyzed by the nonparametric tests of Kruskal Wallis and Dunn, with a significance level of 5%. For all distances and solutions, the values were negative / Doutorado / Dentística / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289476
Date21 August 2018
CreatorsMiranda, Diogo de Azevêdo, 1986-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Lovadino, José Roberto, 1953-, Sotto-Maior, Bruno Salles, Oliveira, Milene de, Lima, Débora Alves Nunes Leite, Aguiar, Flávio Henrique Baggio
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguageMultilíngua
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format36 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0035 seconds