An investigation into the introduction of process analytical technology, using near infrared analysis, to selected pharmaceutical processes

Introduction: Process analytical technologies are systems for the analysis and control of manufacturing processes to assure acceptable end-product quality. This is achieved by timely measurements of critical parameters and performance attributes of raw material and in-process material and processes. The introduction of process analytical technology using near infrared analysis was investigated in three areas, namely incoming raw material analysis, blend uniformity analysis and moisture determination in the fluid bed dryer. Methodology: Incoming raw material identification - The FOSS XDS rapid content analyzer was used for the development of a NIR method for the identification and material qualification of starch maize and lactose monohydrate. Blend uniformity analysis – The SP15 Laboratory Blender fitted with near infrared probe was utilized for the study. Two types of blend experiments were designed to monitor the distribution of magnesium stearate (lubricant) in the blend, namely, a powder blend utilizing lactose monohydrate and a granule blend utilizing Ridaq® granule. Software methods were developed to monitor the standard deviation of the absorbance at the wavelengths that were specific for lactose monohydrate, Ridaq® granule and magnesium stearate. To confirm the prediction of end-point using near infrared, results were verified using an atomic absorption method for magnesium stearate. The blends were sampled at the selected time intervals corresponding to three states of the blend, namely, before end-point, at end-point and after end-point using a sampling plan. An additional six blends were conducted for the granule blend and sampled when the standard deviation had reached a value below 3 x 10-6 at the magnesium stearate wavelength at four consecutive data points (standard deviation value extrapolated from blends carried out to predetermined time intervals). Moisture determination in the fluid bed dryer – Moisture values for two products (Product A and Product B) were retrospectively collected from past production batches. A process capability study was conducted on the moisture values to determine if the current process was in a state of control. Results and Discussion: Incoming raw material identification – The algorithms used for the spectral library were able to distinguish between the raw materials selected. The spectral library positively identified the starch maize and lactose monohydrate samples that were not present in the library. The negative challenge with pregelatinised starch and tablettose demonstrated that the spectral library was able to differentiate between closely related compounds. Blend uniformity analysis – Blends sampled at the predetermined time intervals demonstrated a homogeneous state when the standard deviation of the absorbance was low and a non-homogeneous state when the standard deviation of the absorbance was high, thus near infrared prediction on the state of the blend was confirmed by the standard analytical methods. The series of Ridaq® granule and magnesium stearate blends sampled when the standard deviation was below 3 x 10-6 were homogeneous with the exception of one blend that was marginally out of specification. Blend durations were significantly lower than the standard blend durations used in the facility and ranged from 112 to 198 seconds. Moisture determination in the fluid bed dryer – From the process capability study of the two products it was noted that Product A is stable but can still be optimized while Product B is at a desirable state. The statistical evaluation of the moisture values for Product A and Product B demonstrated that the use of the product temperature to monitor the moisture gave consistent results. The current process is stable and capable of producing repeatable results although near infrared provides a means for continuously monitoring the product moisture and allows one to take action to prevent over-drying or under-drying. Conclusion: From the investigations conducted, it can be seen that there is definitely a niche for process analytical technology at this pharmaceutical company. The implementation is a gradual process of change, which may take time, probably several years (Heinze & Hansen 2005).

Identiferoai:union.ndltd.org:netd.ac.za/oai:union.ndltd.org:nmmu/vital:10153
Date January 2007
CreatorsNaicker, Krishnaveni
PublisherNelson Mandela Metropolitan University, Faculty of Health Sciences
Source SetsSouth African National ETD Portal
LanguageEnglish
Detected LanguageEnglish
TypeThesis, Masters, MSc
Formatxii, 144 leaves, pdf
RightsNelson Mandela Metropolitan University

Page generated in 0.0021 seconds