Return to search

Efeito do cilostazol na hiperplasia neointimal em artérias ilíacas de suínos submetidas a angioplastia transluminal / Effect of cilostazol on neointimal hyperplasia in iliac arteries of pigs after transluminal angioplasty

Objetivo: Avaliar se a administração sistêmica de cilostazol reduz a hiperplasia neointimal nas artérias ilíacas de suínos submetidas a angioplastia com cateter balão. Métodos: O trabalho foi desenvolvido na Unidade de Experimentação Animal do Hospital de Clínicas de Porto Alegre. Vinte suínos foram submetidos a angioplastia com cateter balão 6 x 40 mm na artéria ilíaca comum direita, guiada por ultrassonografia com Doppler. Os animais foram randomizados em dois grupos: grupo 1 (n = 10), no qual foi administrado cilostazol 50 mg em duas doses diárias, e grupo 2 (n = 10), considerado controle. Após 30 dias, os animais foram sacrificados, e as artérias ilíacas preparadas para análise histológica. Os cortes histológicos foram digitalizados e analisados por morfometria digital. A análise estatística foi realizada com o teste t de Student e o de Mann-Whitney. Resultados: Comparando as artérias ilíacas submetidas a angioplastia com as não submetidas a angioplastia, houve hiperplasia neointimal significativa (0,228 versus 0,119 mm2; p = 0,0001). Nas artérias submetidas a angioplastia, não houve diferença entre o grupo 1 (cilostazol) e o grupo 2 (controle) na área do lúmen (2,277 versus 2,575 mm2; p = 0,08), área da íntima (0,219 versus 0,237 mm2; p = 0,64), área da média (2,262 versus 2,393 mm2; p = 0,53) e no percentual de obstrução neointimal (8,857 versus 9,257 %; p = 0,82). Conclusão: O uso de cilostazol 50 mg em duas doses diárias não reduziu a hiperplasia neointimal em artérias ilíacas de suínos submetidas a angioplastia com cateter balão. / Objective: To evaluate whether systemic administration of cilostazol reduces neointimal hyperplasia in the iliac arteries of pigs after balloon angioplasty. Methods: This study was conducted in the Experimental Animal Unit of Hospital de Clínicas de Porto Alegre, Brazil. Twenty pigs underwent angioplasty of the right common iliac artery under Doppler ultrasound guidance using 6x40-mm balloon catheters. The animals were randomized to one of two groups: group 1 (n = 10) received 50 mg cilostazol in two doses a day; and group 2 (n = 10) was the control group. After 30 days, the animals were killed and their iliac arteries were prepared for histological analysis. Histological images were digitalized and analyzed using digital morphometry. The Student t and the Mann-Whitney tests were used for statistical analyses. Results: Iliac arteries that underwent angioplasty had significantly more neointimal hyperplasia than those with no angioplasty (0.228 versus 0.119 mm2; p = 0.0001) Group 1 (cilostazol) and 2 (control) had no significant differences in lumen (2.277 versus 2.575 mm2; p = 0.08), intima (0.219 versus 0.237 mm2; p = 0.64) or media (2.262 versus 2.393 mm2; p = 0.53) area, or in percentage of neointimal obstruction (8.857 versus 9.257 %; p = 0.82). Conclusion: The use of 50 mg cilostazol in two doses a day did not reduce neointimal hyperplasia in iliac arteries of pigs that underwent balloon angioplasty.

Identiferoai:union.ndltd.org:IBICT/oai:lume56.ufrgs.br:10183/53131
Date January 2012
CreatorsLonghi, Joel Alex
ContributorsPereira, Adamastor Humberto
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFRGS, instname:Universidade Federal do Rio Grande do Sul, instacron:UFRGS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds