The diploma thesis deals with the loss of stability of thin-walled flue pipe at coal power plant. The problem of thin-walled structures is their propensity to the loss of stability due to abnormal conditions, for example a vacuum, effect of wind, snow and earthquake. The purpose is to find the optimal deployment of reinforcements so that the model meets the requirements of EN 1993-1-6. This required an evaluation of unreinforced version of the model to identify weaknesses and subsequently other configurations for the application of reinforcement. For determining the resistance the flue pipe to the loss of stability used primarily to access linear bifurcation analysis based on linear analysis, possibly materially nonlinear analysis. The result of work is a design of reinforcement of pipeline which under the requirements of the standard meets the latest model with a reserve of approximately 20 %.