Return to search

Solutions to various problems in reversible cooling fMRI studies / Solutions to various problems in reversible cooling functional magnetic resonance imaging studies

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2003. / Includes bibliographical references (p. 40). / This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. / Functional magnetic resonance imaging (fMRI) has been very useful in helping neuroscientists map the brain. One tool to investigate the interactions between brain regions is to disable a small region in the brain, and look at the functional consequences of this (reversible) inactivation upon regions anatomically connected to the inactivated site. A number of issues need to be resolved before the reversible cooling technique can be used in fMRI studies. The solutions to a number of problems directly related to using reversible inactivation by cooling in conjunction with fMRI experiments on monkey brains are presented in this thesis. Specifically, these include (1) designing a cooling system and cooling probe capable of reversibly cooling the surface cortex of the monkey's brain, (2) develop or use an existing method to measure the temperature distribution with the MR-scanner, and (3) design and construct a coil (phase array) that will be used to obtain temperature and fMRI data at the highest resolution possible. A cooling system and coolant probe were designed capable of changing the temperature of the surface cortex from 37 oC to 20 oC. The Proton Resonance Frequency Shift method, which calculates the temperature based on the phase change between two images, was used to measure the temperature distribution inside an object using an fMRI sequence similar to the one that will be used in the actual experiment. The method was tested and showed an accuracy of ± 0.6 oC as compared with concurrent thermocouple measurements when adjusted for phase drift. A precision of ± 0.15 oC was found at a resolution of 2.1 x 2.1 x 1.0 mm3. A phase array head coil was designed with superior imaging qualities to the current single coil. An increase of SNR from 40 to 52 was observed in the image (30% increase) as compared with the theoretical calculated increase of 70%. / by Mark Haig Khachaturian. / S.M.

Identiferoai:union.ndltd.org:MIT/oai:dspace.mit.edu:1721.1/17030
Date January 2003
CreatorsKhachaturian, Mark Haig, 1979-
ContributorsWim Vanduffel., Massachusetts Institute of Technology. Dept. of Nuclear Engineering., Massachusetts Institute of Technology. Department of Nuclear Engineering, Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
PublisherMassachusetts Institute of Technology
Source SetsM.I.T. Theses and Dissertation
LanguageEnglish
Detected LanguageEnglish
TypeThesis
Format51 p., 1155448 bytes, 2427367 bytes, application/pdf, application/pdf, application/pdf
RightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission., http://dspace.mit.edu/handle/1721.1/7582

Page generated in 0.0127 seconds