Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T11:23:33Z (GMT). No. of bitstreams: 1
Lima_CristinaJardelinode_D.pdf: 804320 bytes, checksum: f36d67c8b410aafe2f3664c02eb674ca (MD5)
Previous issue date: 2014 / Resumo: O objetivo do presente estudo foi comparar, por meio de testes mecânicos e fotoelásticos, o desempenho de parafusos canulados em relação a parafusos convencionais, ambos do sistema 2,3 mm, utilizados na fixação de osteotomia sagital do ramo mandibular. Dez réplicas de mandíbulas humanas fabricadas em poliuretano e uma em resina fotoelástica (Nacional, Jaú, SP, Brazil) foram utilizadas em cada grupo e fixadas em L invertido. Foram realizados testes de carregamento linear vertical em uma máquina de ensaio universal (Instron Corporation, Norwood, MA). O teste Shapiro-Wilk foi realizado para verificar a presença de normalidade entre os resultados (p<0,05), em seguida o teste T foi utilizado para verificar a diferença entre as médias. O teste fotoelástico foi realizado, com o auxílio de um polariscópio plano. A avaliação dos dados do teste fotoelástico foi qualitativa e descritiva. Os resultados mecânicos obtidos demonstraram diferença entre os grupos apenas no deslocamento de 1mm, no qual o parafuso canulado provou ser mais estável. Os resultados da análise fotoelástica revelaram maior tensão entre os parafusos superior anterior e inferior, sendo o parafuso posterior superior o que sofreu menor carga de estresse, o teste revelou ainda franjas de tensão na região de ramo mandibular no grupo convencional. De acordo com os resultados do presente estudo foi possível concluir que os parafusos canulados cônicos apresentaram melhor desempenho nos testes mecânicos em 1 mm de deslocamento e nos testes fotoelásticos, sendo uma opção viável para a fixação da osteotomia sagital do ramo mandibular / Abstract: The aim of the present study was to use mechanical and photoelastic tests to compare the performance of cannulated-screws with that of solid-core screws in sagittal split osteotomy fixation. Ten polyurethane mandibles, with a prefabricated sagittal split ramus osteotomy, were fixed with the inverted L technique and allocated to the following groups: CSG Group, fixed with three 2.3-canullated-screws and SCSG Group, fixed with three 2.3-solid-core-screws. Vertical linear loading tests were performed. The differences between mean values were analysed using the T test for independent samples. The photoelastic test was carried out using a polariscope. The results revealed that there were only differences between the two groups at 1 mm of displacement, at which point the cannulated-screw exhibited more resistance. The photoelastic test confirmed higher stress concentration close to the mandibular branch in the solid-core group. Cannulated-screws performed better than solid-core screws in photoelastic tests and in a mechanical test at 1 mm displacement / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288758 |
Date | 25 August 2018 |
Creators | Lima, Cristina Jardelino de, 1985- |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Moreira, Roger William Fernandes, 1971-, Araujo, Marcelo Marotta, Silva, Alessandro Costa da, Neto, Raul Seabra Guimarães, Marchiori, Érica Cristina |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica |
Source Sets | IBICT Brazilian ETDs |
Language | Multilíngua |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 31 f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds