Return to search

Um algoritmo para alocação ótima de detectores de afundamentos de tensão.

Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-24T17:30:10Z
No. of bitstreams: 1
CAIO MARCO DOS SANTOS JUNQUEIRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 6011061 bytes, checksum: 25c9c9fad6015613e54aae9e700918af (MD5) / Made available in DSpace on 2018-04-24T17:30:10Z (GMT). No. of bitstreams: 1
CAIO MARCO DOS SANTOS JUNQUEIRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 6011061 bytes, checksum: 25c9c9fad6015613e54aae9e700918af (MD5)
Previous issue date: 2017-03-09 / Capes / Um algoritmo para alocação ótima de detectores de afundamentos de tensão (AT)
é apresentado nesta dissertação. O algoritmo utiliza a Transformada Wavelet Discreta
(TWD) paraa detecção de AT e o conceito de Matriz de Observabilidade Topológica
(MOT) para avaliar o desempenho dos Sistemas de Distribuição de Energia Elétrica
(SDEE) quando submetidos à tais distúrbios. Para resolver o problema de alocação ótima
dos dispositivos detectores de AT, utilizou-se o método Binary Particle Swarm Optimi-
tization (BPSO). Adicionalmente, apresenta-se uma metodologia de criação de uma base
de dados para geração automática de AT. O algoritmo foi avaliado considerando-se dois
sistemas: um sistema-testedo IEEE e um SDEE que simula um alimentador real da
cidade de BoaVista-PB, os quais foram simulados no software Alternative Transient Pro-
gram (ATP). Osresultados obtidos indicaram que o algoritmo é capaz de detectar AT
em todo o sistema, fazendo o uso da instalação de detectores em poucas barras, oque
indubitavelmente, reduzirá o custo do sistema de monitoramento. / An algorithm for optimal placement of voltage sags (VS) detectors is presented in this dissertation. The algorithm uses the Discrete Wavelet Transform (DWT) for VS detection and the Topological Observability Matrix (TOM) concept to evaluate the per- formance of the Electric Power Distribution Systems (EPDS) when subjected to such disturbances. In order to solve the problem of optimal placement of the VS detecting devices, the Binary Particle Swarm Optimization (BPSO) method was used. Additionally, a methodology for the creation of a database for automatic VS generation is presented. The algorithm was evaluated considering two systems: an IEEE test system and a EPDS that simulates a real feeder in Boa Vista-PB city, which were simulated in the Alternative Transient Program (ATP) software. The results indicate that the algorithm is capable of detecting VS throughout the system, using the installation of detectors in a few buses, which will undoubtedly reduce the cost of the monitoring system.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/479
Date24 April 2018
CreatorsJUNQUEIRA, Caio Marco dos Santos.
ContributorsSOUZA, Benemar Alencar de., BRITO, Núbia Silva Dantas., NEVES, Washington Luiz Araújo., BRAZ, Helon David de Macedo.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds