Monitoramento da degradação térmica de óleo mineral isolante de transformador utilizando espectroscopia de absorção e fluorescência UV-Vis

Made available in DSpace on 2014-06-11T19:30:49Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-07Bitstream added on 2014-06-13T21:01:23Z : No. of bitstreams: 1
000750418.pdf: 8347882 bytes, checksum: f38265d2f19eb62c9053d91c1e58a41b (MD5) / Neste trabalho verificamos o potencial das técnicas de absorção UV-Vis e de fluorescência para o monitoramento da degradação do óleo mineral isolante (OMI), utilizado em transformadores em função do seu aquecimento. Foram realizadas medições e análise de mapas de contorno (excitação – emissão) de amostras de óleo mineral isolante novo e regenerado não diluídas e diluídas em hexano após aquecimento sistemático das mesmas e retorno à temperatura ambiente. Também foram obtidos espectros de absorção das amostras diluídas. As medições citadas foram realizadas para monitorar a degradação de amostras não diluídas de óleos minerais isolantes novos e regenerados, de forma a verificar a aplicabilidade das técnicas sem um preparo inicial das amostras. Os resultados mostraram que os valores de absorção e fluorescência sofrem mudanças sistemáticas a partir de cerca de 150°C, temperatura na qual a degradação do óleo se torna mais pronunciada. Foram observados comportamentos similares de absorção e fluorescência, tanto para o óleo novo quanto para o regenerado, o que indica que esta técnica óptica simples pode ser usada para o monitoramento contínuo da qualidade do óleo, independentemente da sua fonte. Os possíveis mecanismos responsáveis pelas alterações também são discutidos, tal como o efeito da geometria da configuração experimental das medições de fluorescência. Os resultados fornecem informações para o desenvolvimento de dispositivos portáteis, simples e de custo potencialmente baixo, capazes de verificar a qualidade do óleo mineral isolante em laboratórios e ambientes remotos sem a necessidade de qualquer preparação prévia da amostra. / In this study we verify the potential of the UV-Vis absorption and fluorescence techniques to monitor the degradation of the insulating mineral oil (IMO) used in transformers depending on their heating. Measurement and analysis of contour maps (excitation - emission) were taken from samples of new and regenerated insulating mineral oils diluted and undiluted in hexane after systematically heating and bringing them back to room temperature. Absorption spectra were also obtained from diluted samples. The mentioned measurements were performed to monitor the degradation of new and regenerated insulating mineral oil undiluted samples in order to verify the applicability of the techniques without prior sample preparation. The results showed that the values of absorption and fluorescence underwent systematic changes starting at about 150 °C, temperature at which oil degradation becomes more pronounced. Similar absorption and fluorescence behaviors for both new and regenerated oils were observed, indicating that this simple optical approach may be used for continuous monitoring of oil quality, regardless of its source. The possible mechanisms responsible for the changes are also discussed, and the effect of the geometry of the experimental setup of the fluorescence measurements was investigated as well. The results provide the basis for the development of portable, simple and potentially inexpensive devices, able to check the insulating mineral oil quality in laboratories and remote environments without the need of any prior preparation of the sample.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/100300
Date07 February 2014
CreatorsOmido, Agleison Ramos [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Carvalho, Aparecido Augusto de [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format165 f. : il.color.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0025 seconds