This master thesis is focused on producing orthopaedic implant materials and measuring their corrosion properties. It describes the bone and its structure, types, bone ossification and healing. It defines functions of orthopaedic implants and mentions the types of implants – biodegradable and non-biodegradable. The thesis interprets what corrosion is, what categories of corrosion exist and how does the corrosion influence orthopaedic implants. Preparing the solution of stimulated body fluid and manufacturing samples of different metal combinations (of iron, manganese, phosphorus, magnesium, silver and zinc) is included in this thesis, together with corrosion measurements, microscopic observations, EDAX analysis, metallographic analysis, microhardness testing of samples and pH changes measurements of solutions, and the results are interpreted and explained.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:377338 |
Date | January 2018 |
Creators | Galanová, Zuzana |
Contributors | Vondrák, Jiří, Sedlaříková, Marie |
Publisher | Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |