Return to search

Aplicação de uma valvula de oclusão inspiratoria (VOI) na otimização da ventilação mecanica na fistula broncopleural experimental / Application of the occlusion inspiratory valve in the optimization of mechanical ventilation in bronchopleural fistula experimental

Orientador: Renato Giuseppe Giovanni Terzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-07T22:52:07Z (GMT). No. of bitstreams: 1
Toneloto_MariaGabrielaCavicchia_M.pdf: 2138095 bytes, checksum: 18b0cb653b2350620f763efb13a4c9d7 (MD5)
Previous issue date: 2006 / Resumo: O trabalho realizado em modelo experimental de fístula broncopleural (FBP) visou avaliar os efeitos fisiológicos de uma válvula de oclusão inspiratória (VOI), identificando qual a modalidade ventilatória, o volume corrente ideal e o emprego da PEEP sobre o débito da fístula e de variáveis respiratórias e hemodinâmicas. Foram estudados cinco porcos da linhagem Large White com pulmões normais e peso médio de 25 kg. Todos os animais foram anestesiados, intubados e curarizados. Após controle inicial, foi realizada toracotomia esquerda com a retirada da língula pulmonar, expondo um brônquio de aproximadamente 4 mm, de diâmetro. A seguir, o tórax foi drenado com um sistema em selo d¿água e, posteriormente, fechado. Os animais foram ventilados com volumes correntes de 4 ml/kg, 7 ml/kg e 10 ml/kg, no respirador BIRD 8400, na modalidade controlada, nos modos volume (VCV) e pressão controlados (PCV), associadas ou não à válvula de oclusão inspiratória, associando ou não a PEEP de 10 cmH2O. Foi mantida a freqüência respiratória fixa em 22 ciclos por minuto, a FiO2 em 0,4 e a relação I:E em torno de 1:2. A mecânica respiratória (CO2SMO Plus Dixtal/Novametrix®), variáveis hemodinâmicas (Swan-Ganz) e hemogasométricas (IL-1604), arteriais e venosas mistas, foram registradas nos dois modos ventilatórios (VCV e PCV), antes e após a aplicação de cada tratamento, a saber: VCV ou PCV + ZEEP; VCV ou PCV + PEEP; VOI + ZEEP (VCV ou PCV); VOI + PEEP (VCV ou PCV). Baseados nos resultados obtidos, conclui-se que, neste modelo experimental, o melhor ajuste ocorreu com VC de 10ml/kg associado à VOI com ZEEP. Os modos ventilatórios não foram diferentes. A PEEP, mesmo com volumes correntes baixos, reduz a ventilação alveolar e aumenta o débito da fístula. A PEEP, associada ao modelo de VOI estudado, interfere significativamente com a estabilidade hemodinâmica / Abstract: The objective of this work was to evaluate, in an experimental bronchopleural fistula (BPF) model, the effects of an inspiratory occlusion valve (IOV), identifying the ideal tidal volume and the effect of PEEP on the fistula output and on the respiratory and hemodynamic variables. Five Large White pigs with normal lungs with a mean weight of 25 kg were studied. All animals were anesthetized, intubated and paralyzed with curare. After stabilization, a left thoracotomy was performed and the resection of the lingula exposed a bronchial stump of approximately 4 mm in diameter. The chest wall was hermetically closed with underwater seal drainage. The animals were mechanically ventilated with tidal volumes off 4 ml/kg, 7 ml/kg e 10 ml/kg (BIRD 8400) in Volume Controlled (VCV) and Pressure Controlled (PCV) ventilation, associated, or not, to an IOV, alternating ZEEP and PEEP of 10 cmH2O. Respiratory rate was kept at 22 rpm, FiO2 at 0.4 and the I:E ratio around 1:2. Respiratory mechanics (CO2SMO Plus Dixtal/Novametrix®), hemodynamics (Swan-Ganz catheter) and blood gas parameters (IL-1604) were recorded in both ventilatory modes before and after each treatment: 1 ZEEP; 2. PEEP; 3. IOV + ZEEP; 4. IOV + PEEP. Based on our findings we conclude that, in this experimental model, the best ventilatory strategy was a tidal volume of 10 ml/kg associated with the inspiratory occlusion valve + ZEEP. No difference was observed between VCV and PCV. PEEP, even at low tidal volumes, reduces alveolar ventilation and increases fistula output. PEEP, associated with IOV, significantly interferes with hemodynamic stability / Mestrado / Pesquisa Experimental / Mestre em Cirurgia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311719
Date26 July 2006
CreatorsToneloto, Maria Gabriela Cavicchia, 1978-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Terzi, Renato Gouseppe Giovanni, 1937-, Terzi, Renato Giuseppe Giovanni, Velloso, Marcelo, Araújo, Sebastião
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format88 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds