Microelectronic Measuring Systems (MEMS) are being used to capture kinematic data in real-world environments. The benefits of using MEMS are their small size, relatively low cost (compared to an Optical Motion Capture System) and the ability to capture real-time data in almost any environment. The accuracy and precision of MEMS can be influenced by elements in their surrounding environment such as building materials (i.e., reinforced steel) and structural components (i.e., elevators). Recognizing the influence of the environment on MEMS output is important if the MEMS are to be used in real-world environments where subjects could navigate between various environments. MEMS can also be affected by dynamic motion therefore testing of the MEMS in the same conditions in which they are to be used will help to identify any issues prior to data collection.
The overall purpose of this thesis was to determine if the outputs of four Shimmer 2r MEMS were accurate and precise enough in static and dynamic conditions to use in a future study to assess gait activities of daily living in individuals with a unilateral transtibial amputation. In order to understand the effect of the environment on the MEMS, accuracy and precision were assessed in a rural environment (to reduce the effect of building materials and structural components) as well as the clinical environment where they will eventually be used for research. The MEMS were also evaluated in static and dynamic conditions to better understand how motion affected accuracy and precision.
The results of this study confirmed that the clinical environment affected the MEMS outputs. During the dynamic condition, the gyroscope output of one MEMS sensor was significantly different than the other devices indicating recalibration or possible exclusion from future studies. Prior to using MEMS in research, it is advisable to investigate the effects of the environment on the sensor outputs as well as assess the performance of the individual sensors. / Thesis / Master of Science Rehabilitation Science (MSc) / The overall objective of this thesis was to determine if four Shimmer 2r Microelectronic Measuring Systems (MEMS) were accurate and precise enough in static and dynamic conditions prior to their use in a future study to assess seven activities of daily living (including level walking, ramp walking and stairs) in individuals with a unilateral transtibial amputation in a clinical environment. To understand the effect the environment has on the MEMS, they were assessed in both a rural environment to reduce the effect of building materials, as well as the clinical environment where they will eventually be used for research. This study confirmed that the clinical environment affected the MEMS outputs, although these effects were deemed to be clinically insignificant for the intended purpose of these MEMS. Calibration as well as accuracy and precision assessment of MEMS should be executed in the conditions and environments in which they are to be utilized.
Identifer | oai:union.ndltd.org:mcmaster.ca/oai:macsphere.mcmaster.ca:11375/18297 |
Date | 11 1900 |
Creators | Litman, Karen |
Contributors | MacIntyre, Norma, Rehabilitation Science |
Source Sets | McMaster University |
Language | English |
Detected Language | English |
Type | Thesis |
Page generated in 0.0013 seconds