Saturated reluctance identification of induction motor can be implemented by additional sensor, finite-element method, spectrum analysis, or step voltage test in the research accounts. But it is not easy to implement in the field evaluation when we need to build up the power system model, because of the factory parameter absent, expansive cost, extra sensor installation, or variable voltage and frequency.
To be concerned with practicality, it is always inconvenient to build up simulation for the end user. The linear model of motor can¡¦t provide the simulation answer accurately when models run into saturated during power system transient. Accordingly, this thesis discuss two paragraphs as following:
First, This thesis introduces a simple and practical method base on the manufacturer instruction manual to estimate the saturated reluctance of high / medium voltage induction motor in modeling. And we can analyze the motor dynamic characteristic by using the induction motor d-q-0 model directly, in place of traditional mathematical power equations.
Moreover, we can evaluate the motor-generation reaction because of the rotor inertia due to loss of voltage. To identify the discrepancy between numeral situations what the line capacitor existed or not. Besides, we can explain the existing voltage after power system break down by comparing the simulation result with recorder chart.
Identifer | oai:union.ndltd.org:NSYSU/oai:NSYSU:etd-0610103-224614 |
Date | 10 June 2003 |
Creators | Lee, Ching-Lin |
Contributors | CHWEN CHYN, Whei-Min Lin, Ta-Peng Tsao |
Publisher | NSYSU |
Source Sets | NSYSU Electronic Thesis and Dissertation Archive |
Language | Cholon |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610103-224614 |
Rights | restricted, Copyright information available at source archive |
Page generated in 0.002 seconds