The Implementation of Optimal Control with Sensitivity Reduction to Plant Parameter Variations.

<p> The dual configuration is innovated as a new approach in sensitivity reduction. Three types of sensitivity due to variations in plant parameters are discussed. It has been shown that cost insensitive and terminal insensitive designs are indeed achievable by applying the dual configuration to implement the optimal control. </p> <p> The theory has been developed for a general class of optimal systems and the linear systems with quadratic cost functionals have been analytically evaluated to illustrate the theory. </p> / Thesis / Master of Engineering (ME)

Identiferoai:union.ndltd.org:mcmaster.ca/oai:macsphere.mcmaster.ca:11375/17547
Date04 1900
CreatorsDai, Sue-Hon
ContributorsSinha, N. K., Electrical Engineering
Source SetsMcMaster University
LanguageEnglish