Corrosion of Carbon Steel in Synthetic Coal Liquid Wash Waters

The Potentiodynamic corrosion measuring technique is an electrochemical analytical method which measures corrosion rates of a metal exposed to a corrosive environment.
The corrosion characteristics of carbon steel A1044 in aqueous solutions of aniline hydrochloride,simulating a coal liquid wash water, were determined by this method. The effects of solution velocity and oxygen concentration on the system were also determined.
A bimodal corrosion rate effect was observed in deaerated solutions of 1000 and 5000 ppm chloride as aniline hydrochloride. This effect was interpreted to be the result of the formation of a film on the surface of the specimen.

Identiferoai:union.ndltd.org:WKU/oai:digitalcommons.wku.edu:theses-3321