Cryogenic refractive index of zinc selenide from 8-12 micrometers

I have measured the refractive index of zinc selenide for wavelengths between 8 and 12 mum and temperatures from 85 to 300 K. Each measurement was made by finding the deviation angle of a beam perpendicularly incident on a right triangle prism. The resulting data curves are fitted to polynomials for the temperature dependence and to three different dispersion formulae for the wavelength dependence. I achieved accuracies in the refractive index of ±0.0008 and my results agree well with most previously available data. Refinements to the previously established experimental procedure and error analysis are also presented.

Identiferoai:union.ndltd.org:arizona.edu/oai:arizona.openrepository.com:10150/278265
Date January 1992
CreatorsKnight, Edward Joseph, 1968-
ContributorsWolfe, William L.
PublisherThe University of Arizona.
Source SetsUniversity of Arizona
Languageen_US
Detected LanguageEnglish
Typetext, Thesis-Reproduction (electronic)
RightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.