The beginning of this thesis contains an overview of properties of the insulators, and description of insulators that were used for in depth research of surface breakdown in vacuum. Furthermore, this work focuses on mechanisms of an electric breakdown initiation at the interface of the solid insulator and surrounding low pressure gas. Multiple methods for measurements of dielectric strength are examined. The experimental part describes the measurements performed in the vacuum chamber. The results of these measurements are then analysed. In conclusion, used insulators are compared and suggestions for further work are given.