Attainable Compressive Strength Of Pervious Concrete Paving Systems

The pervious concrete system and its corresponding strength are as important as its permeability characteristics. The strength of the system not only relies on the compressive strength of the pervious concrete but also on the strength of the soil beneath it for support. Previous studies indicate that pervious concrete has lower compressive strength capabilities than conventional concrete and will only support light traffic loadings. This thesis investigated prior studies on the compressive strength on pervious concrete as it relates to water-cement ratio, aggregate-cement ratio, aggregate size, and compaction and compare those results with results obtained in laboratory experiments conducted on samples of pervious concrete cylinders created for this purpose. The loadings and types of vehicles these systems can withstand will also be examined as well as the design of appropriate thickness levels for the pavement. Since voids are supposed to reduce the strength of concrete 1% for every 5% voids(Klieger, 2003), the goal is to find a balance between water, aggregate, and cement in order to increase strength and permeability, two characteristics which tend to counteract one another. In this study, also determined are appropriate traffic loads and volumes so that the pervious concrete is able to maintain its structural integrity. The end result of this research will be a recommendation as to the water-cement ratio, the aggregate-cement ratio, aggregate size, and compaction necessary to maximize compressive strength without having detrimental effects on the permeability of the pervious concrete system. This research confirms that pervious concrete does in fact provide a lower compressive strength than that of conventional concrete; compressive strengths in acceptable mixtures only reached 1700 psi. Extremely high permeability rates were achieved in most all mixtures regardless of the compressive strength. Analysis of traffic loadings reinforce the fact that pervious concrete cannot be subjected to large numbers of heavy vehicle loadings over time although pervious concrete would be able to sustain low volumes of heavy loads if designed properly. Calculations of pavement thickness levels indicate these levels are dependent on the compressive strength of the concrete, the quality of the subgrade beneath the pavement, as well as vehicle volumes and loadings.

Identiferoai:union.ndltd.org:ucf.edu/oai:stars.library.ucf.edu:etd-1472
Date01 January 2005
CreatorsMulligan, Ann Marie
PublisherSTARS
Source SetsUniversity of Central Florida
LanguageEnglish
Detected LanguageEnglish
Typetext
Formatapplication/pdf
SourceElectronic Theses and Dissertations

Page generated in 0.0075 seconds