Orientador : Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T09:18:22Z (GMT). No. of bitstreams: 1
Correa_GiovanideOliveira_M.pdf: 5176132 bytes, checksum: 3f9770e059e64df02a8d6ab5b4053d5b (MD5)
Previous issue date: 2003 / Resumo: A soldagem é uma alternativa para a obtenção de melhor ajuste marginal de retentores metálicos de próteses fixas, de três ou mais elementos. No entanto, há a possibilidade de ocorrerem defeitos nas uniões soldadas ou distorções de todo o conjunto. Embora a adaptação não esteja assegurada, as fundições tipo monobloco são vantajosas quanto à economia de tempo, resistência e durabilidade da infra-estrutura. O propósito desse trabalho foi avaliar o desajuste marginal de infra-estruturas de próteses fixas fundidas em monoblocos, porém obtidas por fundição sobre-modelo refratário, comparando os resultados com os obtidos pela técnica convencional de fundição de próteses fixas. A viabilidade da técnica foi simultaneamente medida em estruturas fundidas em Ti c.p. e nas ligas Ti-6AI-4V e Ni-Cr. Inicialmente uma matriz metálica foi duplicada em silicona por adição para a obtenção dos modelos de trabalho. Sobre os modelos foram encerados os padrões simulando infraestruturas de próteses fixas, correspondendo às fundições convencionais nas três ligas avaliadas. Para a fundição sobre-modelo, a matriz metálica foi duplicada e modelos em revestimento foram obtidos (em Rematitan Plus para as estruturas em Ti c.p. e Ti-6AI-4V e em Talladium, para a liga de Ni-Cr). Sobre os modelos de revestimento foram encerados os padrões simulando as infraestruturas protéticas, sendo o conjunto padrões/modelo refratário, incluído para a realização das fundições. As infra-estruturas após a fundição foram jateadas com óxido de alumínio, ajustadas internamente e acabadas com fresas. Os desajustes marginais foram medidos em microscópio mensurador (STM Olympus - Japão) com aumento de 50 X e precisão de 0,5Ilm. Os valores obtidos foram submetidos a análise de variância e ao teste de Tukey em nível de 5% de significância. Os desajustes médios obtidos para a técnica de fundição sobre-modelo (82,86Ilm para Ti c.p.; 64,41 11m Ti-6AI-4V; e, 77,241lm para Ni-Cr) foram significativamente menores que os obtidos pela técnica convencional (106,36Ilm para Ti c.p.; 75,73!lm Ti-6AI-4V; e, 101,96!lm para Ni-Cr). Para ambas as técnicas, dentre os materiais avaliados, o desajuste marginal foi significativamente diferente, apresentando-se na seguinte ordem decrescente: Ti c.p, Ni-Cr e Ti-6AI-4V / Abstract: Soldering has been an alternative for achieving acceptable marginal fit of metallic crowns of 3-unit fixed frameworks to the respective abutments, in detriment of the single-piece casting. However, defects at the joined areas or distortions of the entire frame are frequent. Although adaptation can not be assured, single-piece casting presents advantages such as time saving, strength and strength of the framework. The purpose of this study was to evaluate the marginal fit of frameworks for fixed prostheses using the method of single-piece casting using a refractory die, comparing the results with the conventional casting technique for fixed prosthodontics. The viability of the technique was simultaneously measured in casting frames fabricated from c.p. Ti and Ti-6AI-4V and Ni-Cr alloys. Initially a metallic cast was prepared and duplicated using addition silicone for making working casts. For the conventional technique, the 3unit simulated frameworks were waxed over the working casts. For the single-piece casting, the metallic cast was duplicated and investment dies were made (Rematitan Plus - c.p. Ti and Ti-6AI-4V; Talladium - Ni-Cr). The frameworks were waxed on the investment casts that were invested for the castings. After casting, the frameworks were air-abraded with aluminum oxide particles, adjusted and finished with the aid of wheels. The marginal fit was measured under a measurer microscope (Olympus - Japan) with X50 magnification and the values were submitted to the Tukey's test at a 5% levei of significance. The mean values for the single-piece casting technique (82,86 jJm - c.p.Ti.; 64,41jJm - Ti-6A1-4V; 77,24jJm - Ni-Cr) were significantly lower than the values for the conventional technique (106,36jJm - c.p.Ti.; 75,73jJm - Ti-6AI-4V; 101,96jJm - Ni-Cr). For both techniques, the marginal fit values for the metais evaluated were significantly different, as follow (from the higher to the lower): c.p. Ti, Ni-Cr e Ti-6AI-4V / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289195 |
Date | 06 May 2003 |
Creators | Correa, Giovani de Oliveira |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Henriques, Guilherme Elias Pessanha, 1968-, Neisser, Maximiliano Piero, Correr Sobrinho, Lourenço |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 118p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0018 seconds