Return to search

Influencia de diferentes tipos de muflas na movimentação de dentes de proteses totais superiores / Influence of different flask types on teeth displacement in complete upper dentures

Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piraciaba / Made available in DSpace on 2018-08-15T04:23:57Z (GMT). No. of bitstreams: 1
Santos_MateusBertoliniFernandesdos_M.pdf: 2329758 bytes, checksum: 359af0abc873ef75f6b0cf7077d9a714 (MD5)
Previous issue date: 2010 / Resumo: O objetivo neste estudo foi verificar a influência de diferentes tipos de muflas na movimentação de dentes ocorrida em próteses totais padronizadas após o processamento laboratorial em ciclo de polimerização longo (74±2°C por 9 horas), em banho de água. A partir de matrizes em silicone, foram obtidos 31 modelos em gesso pedra tipo III de uma arcada desdentada superior e 31 de uma inferior. Sobre um modelo superior foram confeccionada base de prova e plano de orientação em cera com dimensões de 20 mm de altura na região anterior e 10 mm na região posterior. Este plano foi montado em articulador semi-ajustável, e após isso foi confeccionada base de prova e plano de cera inferior seguido pela montagem do modelo inferior no articulador. Após a realização da montagem dos dentes artificiais nos planos de cera, foi confeccionada uma matriz em silicone laboratorial para possibilitar a reprodução da montagem dos dentes. Foram então encerados 30 pares de próteses totais, distribuídos aleatoriamente em três grupos (n=10): Mufla convencional, Mufla Dupla e Mufla HH com os dentes em oclusão. Antes da inclusão pinos referenciais foram colocados em locais padronizados e as distâncias entre incisivos (I-I), pré-molares (P-P), molares (M-M), incisivo a molar do lado esquerdo (IE-ME) e incisivo a molar do lado direito (ID-MD) aferidas em microscópio óptico linear com 0,0005 mm de precisão. Após a polimerização estas distâncias foram aferidas novamente, e os dados obtidos analisados estatisticamente através dos testes t-pareado, ANOVA e Holm-Sidak, todos com 95% de confiança. Foram encontradas diferenças estatisticamente significantes entre as distâncias P-P (p=0,003 para mufla dupla; e p<0,001 para mufla HH) e M-M (p=0,006 para mufla convencional; p=0,005 para mufla dupla; e p<0,001 para mufla HH). Quando comparadas entre si, foi encontrada diferença estatisticamente significante entre pré-molares (p=0,011) sendo que a mufla convencional apresentou menor diferença entre as distâncias pré/pós-polimerização que a mufla HH (p=0,003). Todas as muflas envolvidas neste estudo apresentaram diferenças estatisticamente significantes em ao menos uma das distâncias aferidas, sendo que a mufla convencional apresentou os melhores resultados / Abstract: The aim of this study was to verify the influence of different flask types in the teeth displacement after processing standardized complete dentures in long cycle of polymerization in water bath (9 hours at 74°C). Thirty-one superior and thirty-one inferior stone casts of an edentulous arch were poured with type III stone, from a silicone matrix. One superior cast was mounted in a semi-adjustable articulator with wax rim height of 20 mm in anterior region and 10 mm in the posterior, and then the inferior cast was mounted too. After teeth wax-up, silicone matrix were made with laboratory silicone to enable the reproduction of the same wax-up pattern. The dentures were assigned randomly in 3 groups (n=10): Traditional flask, Double Flask and HH flask with teeth in occlusion. Before flasking reference pins were placed in standardized places and the distances between incisive (I-I), pre-molars (P-P), molars (M-M), left incisor to left molar (LI-LM) and right incisor to right molar (RI-RM) were measured in an optical microscope with 0.0005 mm accuracy. After polymerization, these distances were re-measured and the data obtained was statistical analyzed trough paired t-test, ANOVA and Holm-Sidak, all with 95% of confidence level. It was found statistical differences among P-P (p=0.003 for double flask; and p<0.001 for HH flask) and M-M (p=0.006 for traditional flask; p=0.005 for double flask; and p<0.001 for HH flask). When compared, it was found statistical differences among pre-molars (p=0.011) where conventional flask showed minor differences than HH flask (p=0.003). All flask types used in this study presents statistical differences in at least one of the measured distances, being that traditional flask showed better results / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288553
Date02 October 2010
CreatorsSantos, Mateus Bertolini Fernandes dos, 1985-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Rafael Leonardo Xediek, 1974-, Marchini, Leonardo, Mesquita, Marcelo Ferraz
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageUnknown
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format39 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds