Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-20T14:54:53Z
No. of bitstreams: 1
Teseseg.pdf: 4091406 bytes, checksum: 5c096537a6afa0dc26ceb33ccc3387b7 (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-20T15:53:19Z (GMT) No. of bitstreams: 1
Teseseg.pdf: 4091406 bytes, checksum: 5c096537a6afa0dc26ceb33ccc3387b7 (MD5) / Made available in DSpace on 2016-09-20T15:53:19Z (GMT). No. of bitstreams: 1
Teseseg.pdf: 4091406 bytes, checksum: 5c096537a6afa0dc26ceb33ccc3387b7 (MD5) / CNPQ / Os ditiocarbamatos (carboditioatos) têm sido muito utilizados em operações de pré-concentração de traços de metais por extração (líquido-líquido ou em fase sólida) e co-precipitação. No presente trabalho, apresentam-se os resultados encontrados com a co-precipitação de cobre, níquel, cobalto, chumbo e cádmio empregando piperazina-bis-ditiocarbamato, dietilditiocarbamato e N, N’dibenziletileno bisditiocarbamato sob a forma de compostos do zinco(II).
Os reagentes foram preparados a partir da reação entre uma solução da amina correspondente, dissolvida em etanol, alcalinizada com NaOH e resfriada a 10OC com o dissulfeto de carbono (CS2). O precipitado que se forma é separado por filtração e pode ser usado como solução aquosa 1% (m/v) e pode ser conservado por mais de 15 dias.
O zinco (II) reage com os ditiocarbamatos de sódio correspondentes e precipita, arrastando os demais metais. O procedimento pode ser executado com soluções com valores de pH entre 6,0 e 9,5 e não é afetado pela ordem de adição dos reagentes. O tempo de centrifugação para deposição da fase precipitada é de 15-30 minutos com uma rotação de 1000-2000 rpm. A co-precipitação simultânea de Cd, Co, Cu, Ni e Pb em níveis de 0,2 g/mL em alíquotas de 50,0 mL de água é possível empregando esta metodologia.
As metodologias desenvolvidas foram aplicadas a amostras de água do mar e soluções salinas sintéticas (NaSO4, KCl, NaCl, Na2CO3). Os resultados mostram recuperações superiores a 90% para os metais, exceto para cobalto que tem recuperação superior a 90% apenas quando é empregada a ZnPDC como reagente em soluções salinas 1% (m/v). O método apresentou boa reprodutibilidade e tempo de análise de aproximadamente 4 horas.
A metodologia com ZnPDC foi mais precisa para Co e Cu do que as outras metodologias. Sendo o ZnDDC o menos preciso para estes dois metais.
Foram realizados experimentos com suporte sólido (naftaleno impregnado com ZnDDC) para a extração de Cd, Co, Cu, Ni e Pb. / The dithiocarbamates (carbodithioates) have been used in operations of pre-concentration of lines of metals by extraction (liquid-liquid or in solid phase) and co-precipitation. In the present work we presented results found for copper co-precipitation, nickel, cobalt, lead and cadmium using the zinc(II) compounds of piperazine-bis-dithiocarbamate, diethildithiocarbamate and N, N' dibenzylethylene bisdithiocarbamate.
The reagents were prepared starting from the reaction among a solution of the corresponding amine dissolved in ethanol, alcalized with NaOH and caught a cold to 10O C, with the dissulfide of carbon (CS2). The precipitate that it forms was separated by filtration. The reagent is used as aqueous solution 1% (m/v) and it is stable by 15 days.
The zinc (II) reacts with the sodium dithiocarbamates corresponding and co-precipitating with the other metals. The procedure can be executed with solutions with pH values between 4.0 and 10.0, and it is not affected by the order of addition of the reagents. The time of centrifugation is of 15-30 minutes with a rotation of 1000-2000 rpm. A simultaneous co-precipitation of Cd, Co, Cu, Ni and Pb in levels of 0.2 µg/mL in aliquots of 50.0 mL of water are possible using this methodology.
The developed methodologies were applied the samples of water of the sea and synthetically saline solution s (NaSO4, KCl, NaCl, Na2CO3). The results show recoveries up to 90%, except for cobalt that has recovery around 90% only when the ZnPDC was used as reagent in saline solutions 1%. The method showed god reproducibility and the time’s analysis during around four hours.
The methodology using ZnPDC was more precise to Co and Cu than the others methodologies. The ZnDDC was the less precise for these two metals.
We also used a solid support (naphtalene impregnated with ZnDDC) for the extraction of Cd, Co, Cu, Ni and Pb.
Identifer | oai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/20663 |
Date | 12 1900 |
Creators | Franco Junior, Jorge de Oliveira |
Contributors | Costa, Antonio Celso Spinola |
Publisher | Instituto de Química, Programa de Pós Graduação em Química, IQ, brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0012 seconds