Submitted by DANILO PAZIAN PAULO (danilo.ifsp.bgi@gmail.com) on 2017-07-10T16:09:54Z
No. of bitstreams: 1
Versão Final V1.pdf: 6668672 bytes, checksum: d517c07a2f6f08350724000e0f4d4b64 (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-07-13T20:30:48Z (GMT) No. of bitstreams: 1
paulo_dp_me_ilha.pdf: 6668672 bytes, checksum: d517c07a2f6f08350724000e0f4d4b64 (MD5) / Made available in DSpace on 2017-07-13T20:30:48Z (GMT). No. of bitstreams: 1
paulo_dp_me_ilha.pdf: 6668672 bytes, checksum: d517c07a2f6f08350724000e0f4d4b64 (MD5)
Previous issue date: 2017-05-12 / Dinamômetros biomédicos são equipamentos utilizados para medir forças exercidas pelas mãos. Com o uso deste tipo de equipamento, é possível realizar avaliações biomecânicas das mãos de pacientes que após cirurgias, acidentes ou patologias osteomioarticulares, tiveram redução na sua capacidade de exercer forças com as mãos. O objetivo deste trabalho foi a implementação de um dinamômetro biomédico ergonômico, de fácil utilização, com capacidade de comunicação com diferentes tipos de dispositivos móveis, como smartphones e tablets. O projeto realizado se constitui no aprimoramento de duas versões anteriores de dinamômetros implementadas no Laboratório de Instrumentação Eletrônica e Engenharia Biomédica da UNESP –Campus de Ilha Solteira. Testes em voluntários utilizando o dinamômetro desenvolvido e um dinamômetro comercial da marca SAEHAN, e posterior análise estatística dos dados revelam uma excelente confiabilidade intra-examinador para o dinamômetro desenvolvido, com coeficiente de correlação intraclasse médio de 0,95 entre os diferentes grupos analisados, e de 0,98 para o dinamômetro SAEHAN. A análise estatística revela também uma excelente confiabilidade concorrente para as medidas realizadas pelo dinamômetro desenvolvido em relação às do dinamômetro SAEHAN, sendo de 0,93 para mãos dominantes e 0,92 para mãos não dominantes. Assim, o dinamômetro desenvolvido é confiável, válido e comparável com o dinamômetro SAEHAN quando adotados os mesmos procedimentos de exame de preensão palmar. / Biomedical dynamometers are equipment used to measure forces exerted by the hands. Using this type of equipment, it is possible to perform biomechanical evaluations of the hands of patients that after surgery, accidents or diseases have had a reduction in the ability to exert force with their hands. The objective of this work was the implementation of an ergonomic biomedical dynamometer, easy to use, with ability to communicate with different types of mobile devices such as smartphones and tablets. The project carried out constitutes the improvement of two previous dynamometers versions implemented in the Electronic Instrumentation and Biomedical Engineering Laboratory at UNESP - Ilha Solteira. Volunteer tests using the developed dynamometer and a commercial SAEHAN dynamometer, and subsequent statistical analysis of the data revealed an excellent intra-examiner reliability for the developed dynamometer, a mean of 0,95 among different groups analyzed, and a mean of 0,98 for the SAEHAN dynamometer. The statistical analysis also revealed an excellent concurrent reliability for the measurements performed by the dynamometer developed in relation to those of the SAEHAN dynamometer, being 0,93 for dominant hands and 0,92 for non-dominant hands. Thus, the developed dynamometer is reliable, valid and comparable with the SAEHAN dynamometer when the same grip strength examination procedures were adopted.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/151081 |
Date | 12 May 2017 |
Creators | Paulo, Danilo Pazian [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Carvalho, Aparecido Augusto de [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | 600 |
Page generated in 0.0033 seconds