Return to search

Influência da orientação proximodistal do mini-implante ortodôntico, na distribuição de tensões: análise numérica / Influence of the mesio-distal direction of the miniscrew on stress distribution: numerical analysis

Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-04T21:05:03Z
No. of bitstreams: 1
fernandoluizgoulartcruz.pdf: 3319031 bytes, checksum: b8ba4abba29514e3926b4197c93cdcf2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:23:44Z (GMT) No. of bitstreams: 1
fernandoluizgoulartcruz.pdf: 3319031 bytes, checksum: b8ba4abba29514e3926b4197c93cdcf2 (MD5) / Made available in DSpace on 2016-07-13T16:23:45Z (GMT). No. of bitstreams: 1
fernandoluizgoulartcruz.pdf: 3319031 bytes, checksum: b8ba4abba29514e3926b4197c93cdcf2 (MD5)
Previous issue date: 2012-03-06 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar pelo método de elementos finitos (MEF), a influência da orientação do Mini-implante Ortodôntico (MIO), em relação ao carregamento, na distribuição de tensões no tecido ósseo. Por meio da interface gráfica do programa de elementos finitos Abaqus/CAE, foram confeccionados modelos tridimensionais, correspondentes a um MIO, a uma seção do osso maxilar e dentes pré-molar e molar provenientes de cortes de tomografia computadorizada no formato Dicom. Todas as partes foram consideradas como seções sólidas e homogêneas, com propriedades isotrópicas e lineares-elásticas. Foi aplicada no MIO uma força de 2N, decomposta a 45º em duas componentes sobre o plano normal ao seu eixo longitudinal. Para a simulação numérica, o MIO foi instalado em nove orientações proximodistais diferentes. Uma instalação ortogonal à superfície vestibular (angulação de 0º), outras de -10º, -20º, -30º e -40º a favor da força aplicada e 10º, 20º, 30º e 40º contrários à força aplicada. Por meio do critério de von Mises e da análise das tensões principais observou-se que houve uma variação das tensões em função da orientação, sendo que a situação que ocorreu menor concentração para o osso cortical foi a de 0º, enquanto que a -20º e 20º ocorreram maiores concentrações. Conclui-se que houve influência da orientação proximodistal do MIO, em relação ao carregamento, na distribuição de tensões no tecido ósseo. / The aim of this study was to evaluate, by finite element method (FEM), the influence of load direction on stress distribution in bone tissue around orthodontic miniscrew. By means of the graphic interface of Abaqus/CAE finite element program, tridimensional models were made, corresponding to a miniscrew, section of maxillary bone, premolar and molar teeth taken from computerized tomograph cuts in Dicom format. All parts were considered solid and homogeneous sections with isotropic and linear-elastic properties. A 2N force was applied on the miniscrew, decomposed in two components at 45º on the plane normal to its longitudinal axis. For numerical simulation, the miniscrew was placed in nine different mesio-distal directions. A placement orthogonal to the vestibular surface (angulation of 0º), others of -10º, -20º, -30º and -40º in favor of the force applied and 10º, 20º, 30º and 40º contrary to the force applied. By means of von Mises criteria and analysis of main stressed it was observed that there was a variation in stresses as a result of direction, and the most attenuating situation for the cortical bone was that of 0º, whereas at -20º and 20º higher stress concentrations occurred. It was concluded that there was influence of the mesio-distal direction of the miniscrew in relation to load, of stress distribution in bone tissue.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/1991
Date06 March 2012
CreatorsCruz, Fernando Luiz Goulart
ContributorsLeite, Fabíola Pessôa Pereira, Bastos, Flávia de Souza, Pellizzer, Eduardo Piza, Toledo, Elson Magalhães
PublisherUniversidade Federal de Juiz de Fora, Programa de Pós-graduação em Clínica Odontológica, UFJF, Brasil, Faculdade de Odontologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds