Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-20T15:14:06Z
No. of bitstreams: 1
bernardosottomaiorperalva.pdf: 4608167 bytes, checksum: c63c1f7fc453965f36158791fb85964e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-24T16:49:03Z (GMT) No. of bitstreams: 1
bernardosottomaiorperalva.pdf: 4608167 bytes, checksum: c63c1f7fc453965f36158791fb85964e (MD5) / Made available in DSpace on 2017-04-24T16:49:04Z (GMT). No. of bitstreams: 1
bernardosottomaiorperalva.pdf: 4608167 bytes, checksum: c63c1f7fc453965f36158791fb85964e (MD5)
Previous issue date: 2012-05-07 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesta dissertação, são apresentados métodos para detecção de sinais e estimação de energia para calorimetria de altas energias aplicados no calorímetro hadrônico (TileCal) do ATLAS. A energia depositada em cada célula do calorímetro é adquirida por dois canais eletrônicos de leitura e é estimada, separadamente, através da reconstrução da amplitude do pulso digitalizado amostrado a cada 25 ns. Este trabalho explora a aplicabilidade de uma aproximação do Filtro Casado no ambiente do TileCal para detectar sinais e estimar sua amplitude. Além disso, este trabalho explora o impacto na detecção de eventos válidos e estimação da amplitude quando somam-se os sinais referentes à mesma célula antes da aplicação do filtro. O método proposto é comparado com o Filtro Ótimo atualmente utilizado pelo TileCal para reconstrução de energia. Os resultados para dados simulados e de colisão mostram que, para condições em que a linha de base do sinal de entrada pode ser considerada estacionária, a técnica proposta apresenta uma melhor eficiência de detecção e estimação do que a alcançada pelo Filtro Ótimo empregada no TileCal. / The Tile Barrel Calorimeter (TileCal) is the central section of the hadronic calorimeter of ATLAS at LHC. The energy deposited in each cell of the calorimeter is read out by two electronic channels for redundancy and is estimated, per channel, by reconstructing the amplitude of the digitized signal pulse sampled every 25 ns. This work presents signal detection and energy estimation methods for high energy calorimetry, applied to the TileCal environment. It investigates the applicability of a Matched Filter and, furthermore, it explores the impact when summing the signals belonging to the same cell before the estimating and detecting procedures. The proposed method is compared to the Optimal Filter algorithm, that is currently been used at TileCal for energy reconstruction. The results for simulated and collision data sets showed that for conditions where the signal pedestal could be considered stationary, the proposed method achieves better detection and estimation efficiencies than the Optimal Filter technique employed in TileCal.
Identifer | oai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/4139 |
Date | 07 May 2012 |
Creators | Peralva, Bernardo Sotto-Maior |
Contributors | Cerqueira, Augusto Santiago, Seixas, José Manoel de, Nóbrega, Rafael Antunes, Campos, Marcello Luiz Rodrigues de, Rodrigues, André Massafferri |
Publisher | Universidade Federal de Juiz de Fora (UFJF), Programa de Pós-graduação em Engenharia Elétrica, UFJF, Brasil, Faculdade de Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds