Uma avaliação da influência das janelas de tempo e do período de medição na análise de distorções harmônicas e inter-harmônicas em instalações eólicas / An evaluation of the influence of time windows and measuring period in the analysis of harmonic and interharmonic distortions in wind power installations

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-03-15T18:50:35Z
No. of bitstreams: 1
2016_JéssicaSantoroGonçalvesPena.pdf: 7785177 bytes, checksum: 19c31a231e1c525d812b241b55bf980b (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-03-17T18:24:26Z (GMT) No. of bitstreams: 1
2016_JéssicaSantoroGonçalvesPena.pdf: 7785177 bytes, checksum: 19c31a231e1c525d812b241b55bf980b (MD5) / Made available in DSpace on 2016-03-17T18:24:26Z (GMT). No. of bitstreams: 1
2016_JéssicaSantoroGonçalvesPena.pdf: 7785177 bytes, checksum: 19c31a231e1c525d812b241b55bf980b (MD5) / Convencionalmente, a estimação do conteúdo harmônico e inter-harmônico dos sinais de tensão e corrente, é baseada no uso da Transformada Discreta de Fourier (ou DFT, do inglês Discrete Fourier Transform). Entretanto, o aumento da participação da geração eólica na matriz energética mundial justifica a execução de estudos que avaliem a adequação dos atuais procedimentos de medição das emissões dos mencionados fenômenos. As recomendações tradicionais são baseadas nos padrões IEC 61000-4-7 e IEC 61000-4-30, que, dentre outros aspectos, estabelece que o processamento dos sinais se dê por meio do emprego da DFT com uma janela de tempo retangular de 12 ciclos de 60 Hz e com um período de medição de pelo menos 7 dias. Porém, em sistemas eólicos, é esperada a ocorrência de harmônicas e de inter-harmônicas com variação temporal, o que pode tornar a estimação das componentes espectrais via DFT imprecisa e/ou o período de monitoração de 7 dias inapropriado. Posto isso, este trabalho visa apresentar uma metodologia de análise voltada para a identificação do tamanho da janela de tempo e do período de medição mínimo para o monitoramento das emissões harmônicas e inter-harmônicas no contexto da geração eólica. Para tal, realiza-se uma avaliação comparativa entre uma metodologia de medição oriunda da combinação do Método de Prony com o Filtro de Kalman e uma segunda fundamentada na DFT. Em seguida, utilizando-se ferramentas estatísticas, propõe-se um período mínimo de medição das distorções. A aplicação desta metodologia em sinais reais de tensão oriundos de uma usina eólica evidencia a necessidade de um intervalo de monitoramento mínimo de 3 dias e o uso de uma janela de tempo retangular de 15 ciclos de 60 Hz.
______________________________________________________________________________________________ ABSTRACT / Conventionally, the estimation of harmonic and inter-harmonic contents of voltage and current signals is based on the use of the Discrete Fourier Transform (DFT). However, the increase of the participation of wind power generation in the global energy matrix justifies the carrying out of studies which evaluate the adequacy of the current procedures for measuring emissions of the mentioned phenomena. The traditional recommendations are based on the IEC 61000-4-7 and IEC 61000-4-30 standards, which, among other aspects, establishes that the processing of the signals is given through the use of the DFT with a 60 Hz rectangular time window of 12 cycles and a measuring period of at least 7 days. However, in wind power systems, the occurrence of harmonic and inter-harmonic with time variation, which can render the estimation of the spectral components by the DFT inaccurate and/or the monitoring period of 7 days inappropriate is expected. With that said, this study aims to present a methodology focused on identifying the size of the time window and of the minimum measurement period for monitoring the harmonic and inter-harmonic emissions in the context of wind power generation. For such, a comparative evaluation between a measurement methodology derived from the combination of the Prony method with the Kalman filter and a second based on the DFT is carried out. Then, using statistical tools, a minimum period for measuring distortions is proposed. The application of this methodology in real voltage signals originating from a wind power plant shows the need for a minimum measurement interval of 3 days and the use of a 60 Hz rectangular time window of 15 cycles.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/19702
Date15 January 2016
CreatorsPena, Jéssica Santoro Gonçalves
ContributorsAngarita, Jorge Andrés Cormane, Ferreira Filho, Anésio de Leles
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds