Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2008. / Submitted by Diogo Trindade Fóis (diogo_fois@hotmail.com) on 2009-09-24T11:47:52Z
No. of bitstreams: 1
2008_RaphaelMirandaSouza.pdf: 4668890 bytes, checksum: c1977aaa47de971164fe349b06ff078c (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2009-09-26T12:56:33Z (GMT) No. of bitstreams: 1
2008_RaphaelMirandaSouza.pdf: 4668890 bytes, checksum: c1977aaa47de971164fe349b06ff078c (MD5) / Made available in DSpace on 2009-09-26T12:56:33Z (GMT). No. of bitstreams: 1
2008_RaphaelMirandaSouza.pdf: 4668890 bytes, checksum: c1977aaa47de971164fe349b06ff078c (MD5)
Previous issue date: 2008-10-23 / São investigados o comportamento estrutural e a resistência última à punção de ligações laje-pilar de regiões internas das lajes lisas, com um ou dois furos adjacentes ao pilar, e com ou sem transferência de momento fletor da laje ao pilar. As principais variáveis foram: o posicionamento e as dimensões dos furos, a taxa e a distribuição da armadura de flexão, a armadura de cisalhamento e a excentricidade de carga (relação M(momento transferido ao pilar)/V(força cortante)) na ligação. Foram ensaiadas 19 ligações internas laje-pilar, distribuídas em 2 grupos: o primeiro sem a transferência de momento (Série 1 – 10 lajes), com 1 (uma) ligação sem furo, 5 (cinco) com um furo, 2 (duas) com um furo e armadura de cisalhamento e 2 (duas) com dois furos, tendo como principais variáveis o tamanho e posicionamento dos furos, a taxa e a distribuição da armadura de flexão e a armadura de cisalhamento; e o segundo grupo com transferência de momento (Série 2 – 9 lajes), com 2 (duas) ligações sem furo, 4 (quatro) com um furo e 3 (três) com dois furos, tendo como principais variáveis o tamanho e posicionamento dos furos, a direção e sentido do momento transferido e a excentricidade de carga (relação M/V) igual a 0,50m ou 0,25m na ligação. Foram analisados os resultados de cargas últimas, fissuração, deslocamento vertical, deformações das armaduras de flexão, de cisalhamento e do concreto. O posicionamento dos furos em relação ao pilar, adjacente ao maior ou menor lado, as dimensões dos furos, a taxa e a distribuição da armadura de flexão, a armadura de cisalhamento, a variação da relação Mu/Vu em função do carregamento, e, por conseguinte, da excentricidade, influenciaram o comportamento e a carga de ruptura das lajes. Essas influências foram quantificadas. Os resultados experimentais foram comparados com os estimados pelas normas: CEB-FIP/MC1990, EC2/2004, ACI-318:2005 e NBR 6118:2003. O ACI e o EC2 apresentaram estimativas mais conservadoras, embora tenham apresentado algumas estimativas contra a segurança. A NBR 6118:2003, apesar de baseada em parte no EC2, apresentou estimativas menos conservadoras e com um número maior de estimativas contra a segurança. Recomenda-se que todas as normas passem a considerar o momento causado pela excentricidade do perímetro crítico em lajes com furos e, neste sentido, foram apresentadas propostas de modificações para todas as normas estudadas. ________________________________________________________________________________________ ABSTRACT / The structural behavior and the ultimate punching shear resistance of internal reinforced concrete flat slab-column connections, with one or two holes adjacent to the column, with or without flexural moment transfer of the slab to the column was investigated. Main variables were: hole placing and dimensions, flexural reinforcement layout and ratio, shear reinforcement and the eccentricity of the load (M (moment transferred to column) / V (shear)) ratio at the connection. Nineteen internal slab-column joining were tested, separated in two groups: one without moment transfer (Series 1), with 10 (ten) connections: one without hole, five with one hole, two with one hole and shear reinforcement, and two with two holes; and the second group with moment transfer (Series 2), with 9 (nine) connections: two without hole, four with one hole, and three with two holes. For series 1 the variables were hole placing and dimensions, flexural reinforcement layout and ratio, and shear reinforcement, while for series 2 the variables were the direction and orientation of the applied moment and the eccentricity of the applied load (M/V ratio direction and sense of moment transferred and eccentricity of the load (relation M/V) - 0,50m or 0,25m. Ultimate loads, cracking, deflections, concrete and reinforcement strains were analyzed. The hole placing in relation of the column, adjacent to the smaller or bigger column dimension, the hole dimension, flexural reinforcement rate and placing, shear reinforcement, the variation of relation Mu/Vu in function of the load, and, than, of eccentricity of the load, influenced the slabs behavior and rupture load. These influences were quantified. Test results were compared with the estimations from CEB-FIP/MC1990, EC2/2004, ACI-318:2005 and NBR 6118:2003. ACI and EC2 presented most conservative estimates, although have presented some non conservative estimates. Brazilian NBR, even though being partly based in EC2, presented smaller conservative estimates and more non conservative estimates. A modification on all codes is proposed for taking in account the moment caused by the eccentricity at the critical perimeter for slabs with holes.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/1762 |
Date | 23 October 2008 |
Creators | Souza, Raphael Miranda de |
Contributors | Melo, Guilherme Sales Soares de Azevedo |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds