This thesis investigates the performance of pulse charging, which is believed to be superior to constant current charging in some respects, such as charging efficiency and charging speed. The investigation is focused upon the extensively used secondary batteries, lead-acid batteries. The consecutive orthogonal arrays method is applied to search for the optimum operating variables of pulse charging, including pulse amplitude, duty ratio and frequency of the charging current.
Unfortunately, the experimental results of consecutive orthogonal arrays reveal that charging efficiency is not obviously affected by pulse amplitude, duty ratio or frequency. Instead, charging rate is dominantly influenced by average charging current. These results indicate that pulse charging scheme is not superior to constant current charging. To compare these two charging schemes further, a series of experiments are carried out to discuss the effects of each operating variables. Unfortunately, no evidence from the experimental results can prove the superiority of pulse charging to constant current charging as formerly documented.