Made available in DSpace on 2014-12-17T15:42:17Z (GMT). No. of bitstreams: 1
SeverinaDSO_DISSERT.pdf: 2512071 bytes, checksum: 12a15e7529d5b018959d5e9c644f10cf (MD5)
Previous issue date: 2013-07-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / In this work a study was done using electrochemical cyclic voltammetry and
differential pulse voltammetry for isoniazida (INH), ethambutol (EMB), rifampicina
(RIF) and pyrazinamide (PZA) using the electrode boron-doped diamond (BDD) as
working electrode. It also verified the applicability of the technique of differential pulse
voltammetry in the quantification of the active compounds used in the treatment of
tuberculosis, subsequently applying in samples of pharmaceutical formulation.
Among the four active compounds studied, isoniazid showed the best results for the
detection and quantification using differential pulse voltammetry. At pH 4 and pH 8,
for the calibration curves to INH showed good linearity, with quantification limits of
6.15 mmol L-1 (0,844 ppm) and 4.08 mmol L-1 (0.560 ppm) for the respective pH. The
proposed method can be used to determine drug isoniazid, for recovery values were
obtained in approximately 100% / Neste trabalho foi feito um estudo eletroqu?mico utilizando a voltametria c?clica
e voltametria de pulso diferencial para os f?rmacos isoniazida (INH), etambutol
(EMB), rifampicina (RIF) e pirazinamida (PZA) usando o eletrodo de diamante
dopado com boro (BDD) como eletrodo de trabalho. Foi tamb?m verificado a
aplicabilidade da t?cnica de voltametria de pulso diferencial na quantifica??o dos
princ?pios ativos usados no tratamento da tuberculose, posteriormente aplicando em
amostras de formula??o farmac?utica. Dentre os quatro princ?pios ativos estudados,
a isoniazida apresentou os melhores resultados de detec??o e quantifica??o com o
uso da voltametria de pulso diferencial. Em pH 4 e pH 8, as curvas de calibra??o
para a INH apresentaram boa linearidade, apresentando os limites de quantifica??o
de 6,15 μmol L-1 (0,844 ppm) e 4,08 μmol L-1 (0,560 ppm), para os respectivos pH. O
m?todo proposto pode ser usado para a determina??o de isoniazida em f?rmacos,
pois foram obtidos valores de recupera??o em torno de 100%
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/17761 |
Date | 31 July 2013 |
Creators | Oliveira, Severina Denise Sales de |
Contributors | CPF:01139059980, http://lattes.cnpq.br/2485073932883264, Pontes, Daniel de Lima, CPF:61954225334, http://lattes.cnpq.br/1903229358912987, Castro, Suely Souza Leal de, CPF:05705753896, http://lattes.cnpq.br/9860381828526444, Huitle, Carlos Alberto Martinez |
Publisher | Universidade Federal do Rio Grande do Norte, Programa de P?s-Gradua??o em Qu?mica, UFRN, BR, F?sico-Qu?mica; Qu?mica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds