Return to search

Quantum Dot Applications for Detection of Bacteria in Water

Semiconductor nanocrystals, otherwise known as Quantum dots (Q dots), are a new type of fluorophore that demonstrates many advantages over conventional organic fluorophores. These advantages offer the opportunity to improve known immunofluorescent methods and immunofluorescent biosensors for rapid and portable bacterial detection in water. The detection of the micro organism Escherichia coli O157:H7 by attenuation of a fluorophore’s signal in water was evaluated alone and in the presence of another bacterial species. A sandwich immunoassay with antibodies adhered to SU-8 as a conventional comparison to our novel attenuation detection was also conducted. The assays were tested for concentration determination as well as investigation for cross reactivity and interference from other bacteria and from partial target cells. In order to immobilize the capture antibodies on SU-8, an existing immobilization self-assembly monolayer (SAM) for glass was modified. The SAM was composed of a silane ((3-Mercaptopropyl) trimethoxysilane (MTS)) and hetero-bifunctional cross linker (N-γ-maleimidobutyryloxy succinimide ester (GMBS)) was utilized in this procedure. The SU-8 surface was activated using various acids baths and oxygenated plasma, and it was determined that the oxygenated plasma yielded the best surface attachment of antibodies. The use of direct fluorophore signal attenuation for detection of the target E. coli resulted in the lowest detectable population of 1x10¹ cfu/mL. It was not specific enough for quantitative assessment of target concentration, but could accurately differentiate between targeted and non-targeted species. The sandwich immunofluorescent detection on SU-8 attained the lowest detectable population of 1x10⁴ cfu/ml. The presence of Klebsiella pneumoniae in solution caused some interference with detection either from cross reactivity or binding site blocking. Partial target cells also caused interference with the detection of the target species, mainly by blocking binding sites so that differences in concentration were not discernable. The signal attenuation not only had a better lowest detectable population but also had less measurement error than the sandwich immunoassay on SU-8 which suffered from non-uniformed surface coverage by the antibodies.

Identiferoai:union.ndltd.org:arizona.edu/oai:arizona.openrepository.com:10150/193744
Date January 2009
CreatorsKuwahara, Sara Sadae
ContributorsCuello, Joel, Riley, Mark, Yoon, Jeong-Yeol, Gerba, Charles
PublisherThe University of Arizona.
Source SetsUniversity of Arizona
LanguageEnglish
Detected LanguageEnglish
Typetext, Electronic Dissertation
RightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.

Page generated in 0.002 seconds