Return to search

Estabilização de sistemas de energia elétrica em regime transitório na presença de dispositivos FACTS / Stability of electrical power system in transitional regime in the presence of FACTS devices

Submitted by MARCOS JOSÉ GONÇALVES null (marcosjg@ig.com.br) on 2018-05-22T03:01:06Z
No. of bitstreams: 1
Tese Marcos Jose Goncalves FINAL.pdf: 1783203 bytes, checksum: d48ee12e54924878e9c6e28de57fb570 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-05-22T12:09:34Z (GMT) No. of bitstreams: 1
goncalves_mj_dr_ilha.pdf: 1783203 bytes, checksum: d48ee12e54924878e9c6e28de57fb570 (MD5) / Made available in DSpace on 2018-05-22T12:09:34Z (GMT). No. of bitstreams: 1
goncalves_mj_dr_ilha.pdf: 1783203 bytes, checksum: d48ee12e54924878e9c6e28de57fb570 (MD5)
Previous issue date: 2017-11-28 / Este trabalho apresenta um estudo sobre o controle de Sistema de Energia Elétrica (SEE) com vistas à melhoria da estabilidade transitória por meio da atuação de dispositivos FACTS, neste momento considerando os compensadores em derivação (SVC) e em série (TCSC). Propõe-se a inclusão, em dispositivos pré-existentes, a incorporação de um controle adicional visando atuação em face de transitórios eletromecânicos. A influência dos dispositivos sobre a capacidade de sincronização entre os pares de máquinas, avaliada por meio do fator de efeito é inserida na atuação dinâmica/transitória do sistema. A evolução da trajetória pós-falta do sistema é considerada em relação às fronteiras da chamada Região de Sincronização Positiva (RSP) e simulações foram realizadas usando os sistemas-teste Simétrico de duas áreas e New England para Lei de Controle proposta e conclui-se que esta é efetiva na melhoria da estabilidade transitória do Sistema de Energia Elétrica e, com aprimoramentos, poderá ser incluída em procedimentos de operação em tempo real. / The power system transient stability control is approached by means of FACTS devices, and at this first step the SVC and TCSC devices are considered. A certain device acts upon each pair of machines by means of their synchronization capability which is affected by the corresponding transfer admittance as repeated by the FACTS device. This influence is taken into account by means of a parameter named Effect Factor. The boundaries of a region surrounding the stable equilibrium point named Positive Stability Region are used as reference for critical trajectories and the control action intend to reverse the tendency of the trajectory of leaving this region. In view of the shown tested cases the results are very promising since the proposed control has conduced to improvements in fault critical clearing times and so it has potential to be included in online operation procedures.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/154039
Date28 November 2017
CreatorsGonçalves, Marcos José
ContributorsUniversidade Estadual Paulista (UNESP), Colvara, Laurence Duarte [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation600

Page generated in 0.0024 seconds