Return to search

Adsorption of Perfluoroalkyl Substances from Groundwater Using Pilot and Lab Scale Columns

abstract: Per- and polyfluoroalkyl substances (PFAS) are a group of man-made chemicals that are detected ubiquitously in the aquatic environment, biota, and humans. Human exposure and adverse health of PFAS through consuming impacted drinking water is getting regulatory attention. Adsorption using granular activated carbon (GAC) and ion exchange resin (IX) has proved to be efficient in removing PFAS from water. There is a need to study the effectiveness of commercially available sorbents in PFAS removal at the pilot-scale with real PFAS contaminated water, which would aid in efficient full-scale plant design. Additionally, there is also a need to have validated bench-scale testing techniques to aid municipalities and researchers in selecting or comparing adsorbents to remove PFAS. Rapid Small-Scale Column Tests (RSSCTs) are bench-scale testing to assess media performance and operational life to remove trace organics but have not been validated for PFAS. Different design considerations exist for RSSCTs, which rely upon either proportional diffusivity (PD) or constant diffusivity (CD) dimensionless scaling relationships.

This thesis aims to validate the use of RSSCTs to simulate PFAS breakthrough in pilot columns. First, a pilot-scale study using two GACs and an IX was conducted for five months at a wellsite in central Arizona. PFAS adsorption capacity was greatest for a commercial IX, and then two GAC sources exhibited similar performance. Second, RSSCTs scaled using PD or CD relationships, simulated the pilot columns, were designed and performed. For IX and the two types of GAC, the CD–RSSCTs simulated the PFAS breakthrough concentration, shape, and order of C8 to C4 compounds observed pilot columns better than the PD-RSSCTs. Finally, PFAS breakthrough and adsorption capacities for PD- and CD-RSSCTs were performed on multiple groundwaters (GWs) from across Arizona to assess the treatability of PFAS chain length and functional head-group moieties. PFAS breakthrough in GAC and IX was dictated by chain length (C4>C6>C8) and functional group (PFCAs>PFSAs) of the compound. Shorter-chain PFAS broke through earlier than the longer chain, and removal trends were related to the hydrophobicity of PFAS. Overall, single-use IX performed superior to any of the evaluated GACs across a range of water chemistries in Arizona GWs. / Dissertation/Thesis / Masters Thesis Chemical Engineering 2020

Identiferoai:union.ndltd.org:asu.edu/item:57146
Date January 2020
ContributorsVenkatesh, Krishishvar (Author), Westerhoff, Paul (Advisor), Sinha, Shahnawaz (Committee member), Lind, Marylaura (Committee member), Arizona State University (Publisher)
Source SetsArizona State University
LanguageEnglish
Detected LanguageEnglish
TypeMasters Thesis
Format144 pages
Rightshttp://rightsstatements.org/vocab/InC/1.0/

Page generated in 0.0019 seconds