Current brachytherapy treatment planning systems are unable to accurately calculate dose distributions in the vicinity of brachytherapy sources having active lengths much greater than 5 mm. While low dose-rate ¹³⁷Cs sources are dosimetrically characterized using antiquated along-away tables with simple linear-linear interpolation errors in dose calculation exceeding 30% occur due to algorithm inadequacy. The method presented in this thesis permits dosimetric characterization of elongated brachytherapy sources with active lengths 0 < L < 10 cm for implementation on an FDA-approved clinical TPS. Low- and high-energy photon-emitting sources of Pd-103 and Ir-192, respectively, were examined.
Identifer | oai:union.ndltd.org:GATECH/oai:smartech.gatech.edu:1853/33923 |
Date | 07 April 2010 |
Creators | Bannon, Elizabeth |
Publisher | Georgia Institute of Technology |
Source Sets | Georgia Tech Electronic Thesis and Dissertation Archive |
Detected Language | English |
Type | Thesis |
Page generated in 0.001 seconds