Orientador : Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T16:25:53Z (GMT). No. of bitstreams: 1
Lopes_SergioLucioPereiradeCastro_M.pdf: 3060860 bytes, checksum: e901411ca2ec98db5bad48fc901f3204 (MD5)
Previous issue date: 2002 / Resumo: O presente trabalho teve como objetivo avaliar a qualidade das Imagens do Sistema radiográfico digital DenOptix®, obtidas através de sensores parcialmente dessensibilizados. Para tal objetivo, foi utilizado no
processo, um negatoscópio cujo tempo necessário para a total dessensibilização dos sensores já era conhecido previamente e igual a 130 segundos. Foram determinados tempos parciais de dessensibilização a serem estudados e então obtidas imagens de 10 diferentes segmentos de mandíbulas humanas maceradas, com dose de radiação fixa igual a 840 µGy. De cada um destes, obteve-se dez imagens diferentes, correspondentes aos tempos de dessensibilização a serem estudados, sumarizando no total 100 imagens. Estas foram montadas em pares, onde uma era sempre aquela obtida com o sensor totalmente dessensibilizado e a outra com tempo de dessensibilização a ser estudado. Estes pares, no total de 100, foram analisados por cinco radiologistas, que foram orientados em escolher, de cada par, apenas uma imagem como a de melhor qualidade. Após a análise estatística dos dados, concluiu-se que a dessensibilização parcial de sensores DenOptix, abaixo do tempo preconizado, não evidenciou a presença de ruído nas mesmas. Nestes grupos, não houve diferenças estatisticamente significantes entre as escolhas de imagens de sensores totais e parcialmente dessensibilizadas. Apenas nos grupos em que a imagem era obtida em sensor não dessensibilizado (zero segundo) houve alterações na qualidade das imagens detectadas pelos avaliadores / Abstract: The aim of the present work was to evaluate the DenOptix System images quality, when obtained in partially erased imaging plates. For this goal, was used to erase the imaging plate a lightbox, with erasing time of 130 seconds. Partially erasing times were chosen to be evaluated and then images from 10 diferents human jaw pieces were used, with a radiation dose of 840µGy. In each one of the pieces were taken 10 different kinds of images regarding of the erasing times to be evaluated, 100 images were taken, in total. These images were assembled in pairs, where one was that gotten in an imaging plate totally erased (130 seconds) and the other one was that gotten in a different erasing time. Five dental radiologists, who were said to choose just one image, in each pair, as the best one, analyzed these pairs, in total 100. After statistics studies, the study conc1udedthat images obtained from partially erasing plates, didn't evidence noise. In these groups, there was no significant statistic difference between the choice of total and partially erased images plates as the responsible to show the best image. Just on the groups where the images were obtained from non erased imaging plates (zero seconds) there were quality image changes / Mestrado / Mestre em Radiologia Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290145 |
Date | 09 September 2002 |
Creators | Lopes, Sergio Lucio Pereira de Castro |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Almeida, Solange Maria de, 1959-, Freire, Addah Regina da Silva, Boscolo, Frab Norberto |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 91p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds