Várias zoonoses virais acometem equídeos causando quadros neurológicos, entre as quais a raiva e as encefalites equinas do Leste (EEE) e Oeste (WEE). O diagnóstico clínico geralmente não é conclusivo, o que torna imprescindível o diagnóstico laboratorial. Dados do Laboratório de Diagnóstico de Raiva do Instituto Pasteur de São Paulo, entre os anos 2000 e 2010, mostram que aproximadamente 75% das amostras enviadas foram negativas para raiva, ressaltando a relevância da realização de um diagnóstico diferencial para as encefalites equinas causadas por alfavírus. Os objetivos do estudo foram testar a adequação do uso de multiplex hemi-nested RT-PCR para o diagnóstico de raiva, EEE e WEE em amostras de sistema nervoso central de equídeos e realizar uma análise de custo das reações de cada técnica. Foram utilizados os primers 21G, 304 e 504 dirigidos ao gene N do vírus da raiva, e os primers cM3W, M2W, nEEE e nWEE dirigidos ao gene NSP1 dos vírus da EEE e WEE. Procedeu-se a um estudo preliminar dos primers e de seu uso em uma hemi-nested RT-PCR, avaliando a temperatura ótima de anelamento, a sensibilidade e especificidade analíticas e a reprodutibilidade da técnica em amostras de campo positivas para raiva e para EEE. A partir do protocolo estabelecido na reação de hemi-nested RT-PCR, realizaram-se variações de concentração de reagentes no protocolo para a reação de multiplex hemi-nested RT-PCR. Após o estabelecimento do protocolo para esta reação, os mesmos testes para verificação da sensibilidade e especificidade analíticas e da reprodutibilidade foram realizados, comparando-se os resultados com os obtidos pela hemi-nested RT-PCR. No teste de limiar de detecção, a sensibilidade analítica foi semelhante para as duas técnicas, obtendo-se 10-1,7 para os três vírus padrão CVS, EEEV e WEEV. No teste de limiar de detecção utilizando uma amostra com os três vírus verificou-se uma alta especificidade dos primers, sendo que na reação de multiplex hemi-nested RT-PCR foi possível detectar simultaneamente os três vírus padrão. Não houve diferença nas proporções de amostras detectadas como positivas para raiva obtidas pelas duas técnicas, analisando-se pelo teste exato de Fisher (P=1,0000). No entando, para amostras de campo positivas para EEE, a proporção de amostras detectadas como positivas pela hemi-nested RT-PCR foi maior do que a proporção obtida pela multiplex hemi-nested RT-PCR (P<0,0001). Apesar de não ter sido possível o uso de amostras de campo positivas para WEE nesse estudo, os resultados sugerem que seria possível a detecção pela multiplex hemi-nested RT-PCR. Estes dados sugerem que a técnica de multiplex hemi-nested RT-PCR poderia ser aplicada para detecção de raiva e WEE, mas com limitações para a detecção de EEE. Pela análise de custo dos reagentes, o valor de uma reação de multiplex hemi-nested RT-PCR é semelhante ao de uma hemi-nested RT-PCR, podendo representar uma economia de pelo menos 49,17%. / Several viral zoonoses affect the equids causing neurological diseases, including rabies and Eastern and Western equine encephalitides (EEE and WEE). Clinical diagnosis is often not conclusive, in a way that laboratory diagnosis is essential. Data from the Laboratory of Rabies Diagnosis at the Pasteur Institute of São Paulo, between 2000 and 2010, demonstrate that approximately 75% of submitted equid samples were negative for rabies, emphasizing the importance of achieving a differential diagnosis for equine encephalitis caused by alphaviruses. The aims of this study were to test the suitability of using multiplex hemi-nested RT-PCR for the diagnosis of rabies, EEE and WEE in equids central nervous system samples and to perform a cost analysis of the reactions of each technique. We used the primers 21G, 304 and 504 directed to the N gene of rabies virus, and the primers cM3W, M2W, nEEE and nWEE directed the NSP1 gene of WEE and EEE viruses. A preliminary study of the primers was carried out, as well as their use in a hemi-nested RT-PCR, evaluating the optimal annealing temperature, the analytical sensitivity and specificity and the reproducibility of the technique in positive field samples for rabies and EEE. From the protocol established for the hemi-nested RT-PCR, variations in reagents concentrations for the multiplex hemi-nested RT-PCR protocol were perfomed. After establishing the protocol for this reaction, the same tests to verify the analytical sensitivity and specificity and reproducibility were performed and the results compared to those obtained by hemi-nested RT-PCR. In the detection threshold test, the analytical sensitivity was similar for both techniques, resulting in 10-1.7 for the three virus standard CVS, and EEEV WEEV. In the detection threshold test using a sample with the three viruses, a high specificity of the primers was verified and the multiplex hemi-nested RT-PCR was able to detect the three viruses simultaneously. There was no difference in the proportions of samples detected as positive for rabies obtained by both techniques, according to the Fisher exact test (P = 1.0000). However, for EEE positive field samples, the proportion of samples detected as positive by the hemi-nested RT-PCR was higher than the proportion obtained by multiplex hemi-nested RT-PCR (P <0.0001). Although it was not possible to use WEE positive field samples in this study, the results suggest that its detection would be possible by multiplex hemi-nested RT-PCR. Thus, data suggest that the multiplex hemi-nested RT-PCR technique could be applied to detect rabies and WEE, but with limitations for the EEE detection. For the analysis of reagent costs, the cost of one multiplex hemi-nested RT-PCR is similar to one hemi-nested RT-PCR, and may represent a saving of 49,17% at least.
Identifer | oai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-09102012-173007 |
Date | 10 October 2011 |
Creators | Iamamoto, Keila |
Contributors | Ito, Fumio Honma, Kawai, Juliana Galera Castilho |
Publisher | Biblioteca Digitais de Teses e Dissertações da USP |
Source Sets | Universidade de São Paulo |
Language | Portuguese |
Detected Language | English |
Type | Tese de Doutorado |
Format | application/pdf |
Rights | Liberar o conteúdo para acesso público. |
Page generated in 0.003 seconds