Return to search

Tratamento de efluentes domésticos por sistemas integrados de lodos ativados e membranas de ultrafiltração visando o reúso de água. / Domestic wastewater treatment for integrated systems of activated sludge and ultrafiltration membranes aiming at the water reuse.

No presente trabalho foram estudados sistemas pilotos de tratamento integrado de lodos ativados com sistemas de separação por membranas de ultrafiltração visando o reúso de água. O esgoto bruto utilizado foi originado do Conjunto Residencial associado ao esgoto do restaurante universitário da Universidade de São Paulo. Este esgoto possui características físico-químicas e biológicas similares ao esgoto doméstico. O esgoto utilizado nos sistemas de tratamento foi submetido à pré-tratamento: gradeamento e caixa de areia. Foram montados dois sistemas pilotos: I) sistema piloto recebendo esgoto doméstico primário com sistema de tratamento composto por reator biológico de lodos ativados (500 L de volume) e sistema de separação por membranas de ultrafiltração tipo tubular (1,4 m² de área superficial) externa ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 22,9 ±2,7 L.h-¹.m-² e 17 ±2,7 L.h-¹.m-².bar-¹; valores característicos do permeado em relação à variável turbidez média de 0,3±0,1 UNT, cor aparente média de 31,2±4,6 mg de PtCo.L-¹, sólidos dissolvidos totais de 201±47mg.L-¹ e sólidos suspensos totais não detectável. O sistema de lodos ativados operou em regime de aeração prolongada. II) sistema piloto recebendo esgoto doméstico, após tratamento anaeróbio em reator anaeróbio de fluxo ascendente com manta de lodo (UASB), composto por reator biológico de lodos ativados (1.500 L) e sistema de separação por membrana de ultrafiltração tipo espiral (14,4m² de área superficial) interna ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 16,1 ± 4,1 L.h-¹.m-²; valores característicos do permeado em relação à variável turbidez média 0,2±0,1 UNT, cor aparente média de 25±5 mgPtCo.L-¹ e sólidos suspensos totais não detectável. Em ambos os sistemas as eficiências de remoção de nitrogênio e fósforo podem ser consideradas pequenas. Desta forma, foram adicionados sulfato de alumínio e cloreto férrico no tanque de aeração do sistema piloto II. As dosagens variaram de 40 a 80 mg.L-¹. Os melhores resultados de eficiência de remoção de fósforo solúvel foram obtidos com o sulfato de alumínio (em torno de 79%) na dosagem de 80 mg.L-¹. / A pilot plant integrating an extended aeration activated sludge unit and an ultrafiltration membrane system was constructed and operated aiming at the production of an effluent to be reused in industrial activities. Raw wastewater was collected from a student residential building and from one of the University of São Paulo\'s restaurants. The wastewater characteristics have shown to be very close to conventional domestic wastewaters. This wastewater was submitted to preliminary treatment by screening and subsequent grit removal. Two pilots systems were studied. The first one, treating the preliminary treated wastewater by the activated sludge unit followed by the ultrafiltration membrane system of the tubular type (1,4 m² of surface area). In this case, the membrane was located external to the aeration tank. This system has shown the following main results: average rates of percolate production of 22,9 ±2,7 L.h-¹.m-².bar-¹ and 17 ±2,7 L.h-¹.m-².bar-¹; average characteristic values of the percolate as: turbidity of 0,3±0,1 UNT, apparent Color of 31,2±4,6 mg of PtCo.L-¹, total dissolved solids of 201±47mg.L-¹ and total suspended solids not detectable. The second pilot unit received the effluent from an Upflow Anaerobic Sludge Blanket (UASB) reactor and was composed by the extended aeration activated sludge reactor and an ultrafiltration membrane system of the spiral type (14,4m² of surface area), internal to the aeration tank of the activated sludge unit. This system has shown the following main results: average rates of percolate production of 16,1 ± 4.1 L.h-¹.m-²; average characteristic values of the percolate as: turbidity of 0,2±0,1 UNT, apparent color of 25±5 mgPtCo.L-¹ and total suspended solids not detectable. In both systems, the efficiencies of Nitrogen and Phosphorus removal can be considered as small. To improve the efficiencies of soluble phosphorus removal it has been added aluminum sulphate and ferric chloride to the aeration tank of the second pilot unit. The dosages had varied from 40 to 80 mg.L-¹. The best soluble phosphorus removal (about 79%) was achieved with the dosage of 80 mg.L-¹ of aluminum sulphate.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-09012008-103236
Date30 May 2007
CreatorsCostanzi, Ricardo Nagamine
ContributorsHespanhol, Ivanildo
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguageEnglish
TypeTese de Doutorado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0023 seconds