Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2017-12-13T16:54:10Z
No. of bitstreams: 1
CÉLIO ANÉSIO DA SILVA - TESE (PPGEE) 2014.pdf: 1651226 bytes, checksum: a70dc4864a551f419c02ff41303eaffc (MD5) / Made available in DSpace on 2017-12-13T16:54:11Z (GMT). No. of bitstreams: 1
CÉLIO ANÉSIO DA SILVA - TESE (PPGEE) 2014.pdf: 1651226 bytes, checksum: a70dc4864a551f419c02ff41303eaffc (MD5)
Previous issue date: 2014-05-29 / Capes / Um novo método de obtenção de parâmetros de filtros digitais recursivos (FDR) é apresentado para reduzir o impacto da resposta transitória dos Transformadores de Potencial Capacitivos (TPC) sobre o desempenho dos sistemas de medição, proteção e controle. Assumindo uma topologia predefinida, os parâmetros dos filtros são obtidos a partir da resposta em frequência do TPC de interesse. Diferentemente das técnicas reportadas na literatura, o método se aplica com facilidade a TPC de diferentes classes de tensão e independe das características operacionais do sistema. Para tanto, faz-se necessário conhecer a resposta em frequência do TPC em questão, no espectro de frequência de interesse. A validação do método é realizada através de simulações digitais em tempo real via simulador RTDSTM (Real Time Digital Simulator). As análises são baseadas em dados de sistemas elétricos reais e no funcionamento dinâmico dos filtros através da estimação dos fasores das tensões e estudos de localização de falta. A partir dos resultados obtidos, verifica-se que a presença dos FDR reduz significativamente os erros de medição causados pelos TPC quando submetidos a condições transitórias. Portanto, os FDR surgem como uma forma simples e de baixo custo para melhorar o desempenho e a confiabilidade dos sistemas de medição, proteção e controle. / A new method for obtaining recursive digital filter (FDR) parameters is presented in order to reduce the impact of Coupling Capacitor Voltage Transformer (CCVT) transient response on the performance of the measurement, protection and control systems. Assuming a pre-defined topology, the filter parameters are obtained from the CCVT frequency response of interest. Unlike the techniques reported in the literature, the method applies easily to CCVT of different voltage classes and it does not depend on the operating characteristics of the system, therefore, it is necessary to know the frequency response of the CCVT on the frequency spectrum of interest. The method is validated is through digital simulation using the RTDSTM (Real Time Digital Simulator). The analyzes are based on data obtained from electrical systems in service and on the dynamic performance of the filters by estimating the phasors of voltages and fault location studies. It is shown that the presence of FDR significantly reduces measurement errors caused by CCVT when subjected to transient conditions, therefore, the FDR arises as a simple and low cost alternative to improve the performance and reliability of measurement systems, protection and control.
Identifer | oai:union.ndltd.org:IBICT/oai:localhost:riufcg/181 |
Date | 13 December 2017 |
Creators | SILVA, Célio Anésio da. |
Contributors | http://lattes.cnpq.br/3107104665517286, http://lattes.cnpq.br/3630883713661678, NEVES, Washington Luiz Araújo., FERNANDES JÚNIOR, Damásio., BRETAS, Arturo Suman., SOUZA, Benemar Alencar de., MOTA, Wellington Santos., BOAVENTURA, Wallace do Couto. |
Publisher | Universidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0025 seconds