Submitted by Maicon Juliano Schmidt (maicons) on 2015-05-05T14:17:01Z
No. of bitstreams: 1
Leila Maria Tamanini Roman.pdf: 1478472 bytes, checksum: 52db0d09c275b5afd54c35d29758e75d (MD5) / Made available in DSpace on 2015-05-05T14:17:01Z (GMT). No. of bitstreams: 1
Leila Maria Tamanini Roman.pdf: 1478472 bytes, checksum: 52db0d09c275b5afd54c35d29758e75d (MD5)
Previous issue date: 2013-01-01 / Nenhuma / Este trabalho apresenta uma avaliação energética, através do software EnergyPlus, de uma sala externa com climatização e um prédio de sete andares com ventilação natural. Para tanto, monitoram-se o consumo de energia mensal, os dados climáticos, características arquitetônicas, número de funcionários, localização e demais características que possam interferir direta ou indiretamente no consumo de energia do ambiente de estudo. Os dados obtidos através de levantamento in loco, memoriais da área de infraestrutura e recursos humanos, juntamente com a análise das faturas de energia elétrica mensais, servem de parâmetro para a simulação, bem como validam os resultados, permitindo a busca de novas alternativas que visem eficiência e redução no consumo. As avaliações são realizadas tendo como base duas edificações pertencentes ao Centro Administrativo de Lojas Colombo, localizadas em Farroupilha, Rio Grande do Sul. A análise visa minimizar o consumo de energia elétrica buscando garantir o máximo de horas em conforto. Para tanto avalia os índices de conforto térmico, as temperaturas internas, os ganhos internos de calor, as condições de operação do ar condicionado na sala externa e a potência necessária de ar condicionado para instalação nas quinze zonas térmicas pertencentes ao prédio, verificando o consumo energético das alternativas utilizadas e a relação custo-benefício. Através das simulações na sala externa constatou-se que, com a utilização de materiais eficientes termicamente, as trocas térmicas do interior com o exterior são minimizadas, o mesmo ocorrendo com a substituição de equipamentos antigos, a exemplo de monitores de tubo. Nas quinze zonas térmicas do prédio, a instalação de um sistema de ar condicionado se apresenta como alternativa para melhorar os índices de conforto térmico em dias com temperaturas mais elevadas ou mais baixas, situações estas em que a ventilação natural não é suficiente para garantir um ambiente confortável. Esta adequação de climatização dos ambientes elevou o consumo com energia elétrica total do prédio em 17%, contudo ocorreu melhora significativa nos índices de conforto térmico. Na sala externa foi obtida uma redução no consumo de energia elétrica de 14% sobre o consumo total e a garantia de 86% de horas ocupadas em conforto. / This study presents the energetic evaluation, through the software EnergyPlus, of an external room with acclimatization and of a seven-story building with natural ventilation. For this, the monthly energy consumed, the climatic data, the architectonic characteristics, the number of people, the location and other characteristics which can interfere directly or indirectly the room’s energy consumption were monitored. The data obtained through in loco survey, memorials of the infrastructure area and human resources, as well as the analysis of the monthly electrical energy bills, are considered as parameters for the simulation and they validate the results, allowing the search for new alternatives that aim at consumption efficiency and reduction. The evaluations are performed based on two buildings which are part of Centro Administrativo de Lojas Colombo, located in Farroupilha, Rio Grande do Sul, Brazil. The analysis aims at minimizing the electric energy consumption with the purpose of ensuring the maximum of comfort hours, so it evaluates the indexes of thermal comfort, the inside temperatures, the inside heat gains, the operation conditions of the air-conditioning in the outside room, and the necessary air-conditioning power for the installation in the fifteen thermal zones which belong to the building, verifying the energetic consumption of the used alternatives and the cost-benefit ratio. Through the simulations in the outside room, it was detected that with the use of thermally efficient material, the thermal exchanges between inside and outside are minimized, the same occurs with the substitution of old equipment, such as tube monitors. In the fifteen thermal zones of the building, the installation of an air-conditioning system is an alternative to improve the thermal comfort indexes in days with higher or lower temperatures. These are situations in which the natural ventilation is not enough to ensure that the environment is comfortable. The air conditioning simulated increased the building energy consumption in 17%, although a significative increase in thermal comfort was achieved. At the external room a 14% reduction in electricity consumption, over the total consumption, and the guarantee of 86% of occupied hours in comfort was obtained.
Identifer | oai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/3428 |
Date | 11 April 2013 |
Creators | Roman, Leila Maria Tamanini |
Contributors | http://lattes.cnpq.br/3438508833347823, Wander, Paulo Roberto |
Publisher | Universidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Mecânica, Unisinos, Brasil, Escola Politécnica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds