Return to search

Quantificação de nitrofurazona e de nitrofurantoína em medicamentos por espectrofotometria de refletância difusa e de transmissão / Measurement of nitrofurazone and nitrofurantoin drugs in spectrophotometric diffuse reflectance and transmittance

Orientador: Matthieu Tubino / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-20T20:30:33Z (GMT). No. of bitstreams: 1
Palumbo_MarciodasNeves_M.pdf: 1659500 bytes, checksum: ddb5651da213baa8f6c6d2bc06bf367d (MD5)
Previous issue date: 2011 / Resumo: A nitrofurazona e a nitrofurantoína são substâncias derivadas dos nitrofuranos e comercializadas em preparações farmacêuticas com ação bactericida, antifúngica e antimicrobiana com um amplo espectro de aplicação. Apresentam coloração amarela e comprimento de onda de máxima absorção em 370 nm. A maior parte das substâncias pertencentes ao grupo dos nitrofuranos, tem baixíssima solubilidade em água o que dificulta o desenvolvimento de métodos analíticos, sem o uso de solventes orgânicos. Neste trabalho foi desenvolvida metodologia para a determinação do teor de nitrofurazona e de nitrofurantoína em medicamentos por refletância difusa. Para a nitrofurantoína a medida é direta no fármaco, sem uso de qualquer solvente, enquanto que, para nitrofurantoína dissolve-se o fármaco em polietilenoglicol e mede-se a refletância em seguida. A técnica de refletância envolveu, para fins de comparação, a utilização de dois equipamentos distintos: (I) um espectrofotômetro Shimadzu UV-2450 com assessório de refletância e; (II) um refletômetro portátil construído em nosso laboratório. Também foram desenvolvidos duas metodologias para a análise quantitativa dos dois fármacos por transmissão em solução aquosa. Ambos os métodos na região uv-visível do espectro. Os resultados dos dois procedimentos foram comparados entre si e também com aqueles obtidos pela método oficial em high performance liquid cromatagraphy (HPLC), usando o método estatístico t pareado de Student e o teste F de Snedecor. Foi observada total concordância entre os diferentes procedimentos em nível de confiança de 95%. Entre os métodos utilizados, o de refletância difusa apresenta a maior simplicidade operacional podendo ser recomendado o seu uso para quantificação das substâncias estudadas em fármacos. Foram obtidos desvios padrão relativos (DPR) de 3,9 (I) e 5,2% (II) para a nitrofurazona e de 3,4 (I) e 8,0% (II) para nitrofurantoína, enquanto que pelo HPLC os DPR foram 4,4 e 1,8% respectivamente. O método de refletância apresenta significativa vantagem para determinação de nitrofurazona em pomadas em relação ao método oficial pela grande simplicidade operacional. Uma característica interessante do método refletométrico proposto para nitrofurazona é que, apesar de ser quantitativo, não há necessidade de pesagem de alíquota. Quanto ao método de transmitância o DPR ficou em 1,0% para nitrofurazona e 2,2% para nitrofurantoína / Abstract: Nitrofurazone and nitrofurantoin are derivatives substances from nitrofurans and are traded in pharmaceutical preparations with bactericidal , antifungal and antimicrobial actions with a broad spectrum of application. They have yellow coloration and a wavelength of maximum absorption at 370 nm. Most of the substances that belong to the group of nitrofurans have very low solubility in water which complicates the development of analytical methods, without the use of organic solvents. This research developed methodology for the determination of nitrofurazone and nitrofurantoin in drugs by diffuse reflectance. For nitrofurantoin the measure is directly on the drug, without using any solvent, whereas nitrofurantoin is dissolved in polyethylene glycol and the reflectance is measured after. The reflectance techniques involved, for comparison purposes, the use of two different equipment (I) a Shimadzu UV-2450 spectrophotometer with accessory of reflectance and (II) a portable reflectometer constructed in our laboratory. We have also developed two methodologies for quantitative analysis of the two drugs in aqueous solution by transmission. Both methods in the uv-visible region of the spectrum. The results of both procedures were compared between each other and also with those obtained by official method in high performance liquid cromatagraphy (HPLC), using the statistical method t paired of Student and the test and F of Snedecor. It was observed complete agreement between the different procedures in a accuracy level of 95%. Among the methods used, the diffuse reflectance has the highest operational simplicity and it can be recommended its use for quantification of the substances studied in drugs. It was obtained relative standard deviation (RSD) of 3.9 (I) and 5.2% (II) for nitrofurazone and 3,4 (I) and 8.0% (II) for nitrofurantoin, while at the HPLC RSD were 4.4 and 1.8% respectively. The method of reflectance has a significant advantage for the determination of nitrofurazone ointments in relation to the official method due to the great operational simplicity . An interesting feature of the refletocmetric method proposed to nitrofurazone is that, despite being quantitatively, there is no need to weigh the aliquot. As the method of transmittance the DPR was 1.0% to nitrofurazone 2.2% to nitrofurantoin / Mestrado / Quimica Analitica / Mestre em Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/248827
Date09 December 2011
CreatorsPalumbo, Marcio das Neves, 1972-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tubino, Matthieu, 1947-, Pezza, Helena Redigolo, Rossi, Adriana Vitorino
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Química, Programa de Pós-Graduação em Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format61 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0031 seconds