Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2015. / Made available in DSpace on 2015-11-17T03:08:34Z (GMT). No. of bitstreams: 1
335894.pdf: 3270568 bytes, checksum: 8cd03704da81158faacc9c281b2f2785 (MD5)
Previous issue date: 2015 / Sistemas de refrigeração, tais como refrigeradores e congeladores, têm comportamento dinâmico lento. Esse fato contribui sobremaneira para que os ensaios relacionados ao controle de qualidade na produção dos mesmos demandem elevados tempos e, consequentemente, custos. Este trabalho analisa, de forma experimental, grandezas alternativas às tradicionalmente usuais - temperaturas no interior do sistema; potência consumida no transiente de partida do compressor - com potencial de indicação de defeitos em tempos reduzidos. Para tal análise, foram provocados e emulados defeitos de forma controlada em refrigeradores domésticos. A partir de revisão bibliográfica e de contato com especialistas de empresas fabricantes de sistemas de refrigeração e de componentes, foram identificados três defeitos típicos: obstrução na linha de líquido; vazamentos internos ao compressor; carga de fluido refrigerante fora do valor nominal. Três refrigeradores foram empregados como estudo de caso. Individualmente, os resultados foram bons, porém, quando analisados comportamento médio dos três refrigeradores, observou-se grande dispersão de comportamento. Os resultados mostraram que as formas propostas de aplicação de defeitos foram satisfatórias e passíveis de aplicação em investigações futuras, seguindo a linha deste trabalho. Quanto às grandezas analisadas para caracterização de defeitos, houve indicativo de potencial aplicação, em especial da potência elétrica. Porém, há necessidade de aprofundamento dos estudos para efetiva validação dos resultados alcançados.<br> / Abstract : Refrigeration systems as freezers and household refrigerators have slow dynamic behavior. Quality tests in these products production lines demand extensive time and costs. The current work analyses alternative features and properties, based on the systems quantities, with potential to reduce the demanded time in these tests by an experimental approach. To reach this objective, defects were emulated and applied on household refrigeration systems in a controlled way. From the literature review and the contact with refrigeration systems manufacturers experts three typical defects were identified: liquid line restriction; compressor inner leakages; refrigerant fluid overcharge and undercharge. Three household refrigerators were used as case of study. Individually, they presented good results, however large dispersions were found in the sample results composed by the three refrigerators. In the other hand, the proposed methods for application and emulation of defects were validated and may be used in this work line future applications. Electrical power consumption was identified as the most potentially capable quantity to identify defects on the analyzed refrigeration systems. Nevertheless deeper researches may be done to validate the achieved results.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/136481 |
Date | January 2015 |
Creators | Gomes, Gregory Chagas da Costa |
Contributors | Universidade Federal de Santa Catarina, Flesch, Carlos Alberto |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 162 p.| il., grafs., tabs. |
Source | reponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0018 seconds