Magnetická pole pro biomedicínské experimenty / Magnetic fields for biomedical experiments

In this work deals with magnetic fields for use in biomedicine. This solution involves the choice of the correct geometric arrangement of coils for generating magnetic field with a homogeneous distribution of magnetic induction of the widest possible area. The paper compares thre traditional types of coils, solenoid, toroid and Helmholtz coil. For Helmholtz and solenoid coil and is then carried out an analysis of the magnetic flux density in the inner space. Next part is devoted to electrical resonance in the LC circuit. This is then utilized for the development of pulsed magnetic field in the Helmholtz coil. It summarizes the theoretical and practical knowledge to design and construction of resonant converters. The end is devoted to the measurement of circuit parameters and verification of theoretical knowledge.

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:218798
Date January 2010
CreatorsOtýpka, Jan
ContributorsCipín, Radoslav, Patočka, Miroslav
PublisherVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess