Return to search

Verification of Ionospheric tomography using MIDAS over Grahamstown, South Africa

Global Positioning System (GPS) satellites and receivers are used to derive total electron content (TEC) from the time delay and phase advance of the radiowaves as they travels through the ionosphere. TEC is defined as the integralof the electron density along the satellite-receiver signal path. Electron densityprofiles can be determined from these TEC values using ionospheric tomographic inversion techniques such as Multi-Instrument Data Analysis System (MIDAS).This thesis reports on a study aimed at evaluating the suitability of ionospheric tomography as a tool to derive one-dimensional electron density profiles, using the MIDAS inversion algorithm over Grahamstown, South Africa (33.30◦S, 26.50◦E). The evaluation was done by using ionosonde data from the Louisvale (28.50◦S, 21.20◦E) and Madimbo (22.40◦S, 30.90◦E) stations to create empirical orthonormal functions (EOFs). These EOFs were used by MIDAS in the inversion process to describe the vertical variation of the electron density. Profiles derived from the MIDAS algorithm were compared with profiles obtained from the international Reference Ionosphere (IRI) 2001 model and with ionosonde profiles from the Grahamstown ionosonde station. The optimised MIDAS profiles show a good agreement with the Grahamstown ionosonde profiles. The South African Bottomside Ionospheric Model (SABIM) was used to set the limits within which MIDAS was producing accurate peak electron density (NmF2) values and to define accuracy in this project, with the understanding that the national model (SABIM) is currently the best model for the Grahamstown region. Analysis show that MIDAS produces accurate results during the winter season, which had the lowest root mean square (rms) error of 0.37×1011[e/m3] and an approximately 86% chance of producing NmF2 closer to the actual NmF2 value than the national model SABIM. MIDAS was found to also produce accurate NmF2 values at 12h00 UT, where an approximately 88% chance of producing an accurate NmF2 value, which may deviate from the measured value by 0.72×1011[e/m3], was determined. In conclusion, ionospheric tomographic inversion techniques show promise in the reconstruction of electron density profiles over South Africa, and are worth pursuing further in the future.

Identiferoai:union.ndltd.org:netd.ac.za/oai:union.ndltd.org:rhodes/vital:5497
Date January 2008
CreatorsKatamzi, Zama Thobeka
PublisherRhodes University, Faculty of Science, Physics and Electronics
Source SetsSouth African National ETD Portal
LanguageEnglish
Detected LanguageEnglish
TypeThesis, Masters, MSc
Format78 pages, pdf
RightsKatamzi, Zama Thobeka

Page generated in 0.0051 seconds