A substrate was developed for measuring the milk clotting strength of rennet preparations on an automatic clot-timer . The substrate contained 8 percent pasteurized skim milk solids, 1 percent chloroform, 0.3 percent 200 bloom gelatin, 0.03 M added CaCl2 and was buffered to pH 6.6 with 0.057 M cacodylic acid and 0.042 M triethanolamine. The substrate was shelf-stable for 18 days at room temperatures. It was found that rennet preparations could be standardized to within 1 percent of each other, in terms of milk clotting strength, by use of the substrate on the automatic clot-timer. The method appears to have advantages over conventional rennet standardizing procedures. The research included studies on the effect of chloroform, nonfat dry milk and CaCl2 concentrations; heat and ionizing radiation on the substrate coagulation time.
Identifer | oai:union.ndltd.org:UTAHS/oai:digitalcommons.usu.edu:etd-6171 |
Date | 01 May 1973 |
Creators | Stevens, Mark Brimhall |
Publisher | DigitalCommons@USU |
Source Sets | Utah State University |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | All Graduate Theses and Dissertations |
Rights | Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu. |